EOLO MAIOR @
- FLUE PRESSURE SWITCH (5)
This is positioned in the top inner part of the sealed chamber and, by means of the points provided, reads
the difference in pressure between the top of the draught diverter (the point where the extractor is
positioned and operates) and the inside of the sealed chamber.
The signal measured from the pressure switch varies according to the length of the extraction/exhaust
terminals and is measured by the special pressure points fitted to the top part of the sealed chamber (8-
9).
Its operation causes a deviation of a switch contact that acts on the unit (IGN. BOARD) and enables or
fails to enable burner ignition.
- FAN (4)
The extractor operates downstream of the combustion chamber and is physically "rested" on the top part
of the hood (3) from which it extracts fumes into the exhaust pipes to which the boiler is linked.
It is controlled from the ignition unit and its operation coincides with that of the boiler.
The fans used differ according to the output of the appliance
(21,000, 24,000 and 27,000 kcal/h).