Indications and alarms.
The EOLO Maior kW boiler signals malfunctions with the
flashing of one of the LEDs, from 5 to 11, coupled to the
(alternate)
flashing of LED 1.
Operating indications
LED
Remote display
Boiler powered but no flame
LED 1 on
--
Burner on
LED 2 on
--
Chimneysweep function on
LED 3 and 4 simultaneous
flashing (
)
E07
Connection to the CAR
LED 3 and 4 on fixed
(
)
Operating malfunction signalled
LED
flashing
Remote display
CAR offline malfunction, not compatible or RS232 offline
LED 3 and 4 flashing alter-
nately (
)
E31
No ignition block
LED 5 ( )
E01
Flue pressure switch failure
LED 6 (
)
E11
Insufficient system pressure
LED 7 (
)
E10
Insufficient circulation
LED 8 (
)
E27
Delivery NTC probe malfunction
LED 9 (
)
E05
D.h.w. NTC probe malfunction
LED 10 ( )
E06
Overheating safety thermostat block
LED 11 ( )
E02
Electromechanical contacts block*
LED 6 (
) and LED 10
( ) flashing simultaneously
E02 + E04
flashing alternately
Parasitic flame block*
LED 2 ( ) and LED 11 ( )
flashing simultaneously
E02 + E20
flashing alternately
* from December 2005