39
STEMkW Special ed 01/08
EOLO Mini kW Special
Technical Documentation
Technical Documentation
The burner stays on after the first
10 seconds.
No
LED n°6 flashes
(wait for the board to perform 2 ignition cycles)
See "no ignition block" - c
Yes
LED n°4 flashes
Yes
See "insufficient circulation"
LED n°7 flashes
Yes
See "no overheating safety thermostat" - b
No
The boiler reaches and
stays at the set heating
temperature.
No
Check the maximum
heat parameter and
adjust it to maximum
if necessary.
See section D
Yes
The heating request is satisfied.
The boiler reaches and
maintains the set DHW
temperature.
No
See section D
No
Check that:
- the withdrawal of domestic hot water
is not greater than that the boiler can
distribute (see technical data, power,
flow rate, delta T°)
- the domestic hot water exchanger is
clean, replace it if necessary.
Yes
The domestic hot water request is satisfied.