6
STEMkW Special ed 01/08
EOLO Mini kW Special
Technical Documentation
Technical Documentation
Legend:
1 - D.h.w. flow switch
2 - Flow limiter
3 - Filling valve
4 - Gas valve
5 - Burner
6 - Primary heat exchanger
7 - Flue hood
8 - Fan
9 - Sealed chamber
10 - Flue pressure switch
11 - Flow probe
12 - Safety thermostat
13 - System expansion vessel
14 - Automatic vent valve
15 - Boiler pump
16 - D.h.w. heat exchanger
17 - 3-way valve (motorized)
18 - Automatic by-pass
19 - Draining valve
20 - 3-bar safety valve
G - Gas supply
AC - Domestic hot water flow
AF - Domestic cold water inlet
R - System return
M - System flow
Hydraulic circuit.
The primary circuit, with relevant control and safety devices,
is operated
each time either a central heating or d.h.w.
request is made.
Operation.
The heat contained in the fumes produced by combustion
is absorbed by the copper blades of the water-gas primary
exchanger (6) which, in turn, transfers it to the water circula-
ting inside thanks to the boiler circulator (15).
The water is transferred directly into the system or can be
deviated to the instant stainless steel plate exchanger (16).
This depends on the position of the motorised 3-way diverter
valve (17) which, when idle allows the water to flow to the
d.h.w. exchanger (16) while if a central heating request is
made it deviates the flow to the system’s flow (M) and return
(R) pipes.
Primary circuit (Boiler Circuit).
The hot water for central heating and domestic use is produ-
ced by a primary and a secondary (d.h.w.) circuits that work
as required.