13
C
32
C
32
C
32
C
32
1-17
1-19
1-18
1-16
1
2
3
6
4
7
5
1
2
3
6
8
4
7
5
MAKS 45%
MAKS
MAKS
MAKS 45%
INS
TALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
AN
The fixing plate kit includes:
N° 1 - Gasket (1)
N° 1 - Female concentric flange (2)
The Kit includes:
N° 1 - Concentric intake-exhaust pipe Ø
60/100 (3)
N° 1 - Wall sealing plate (4)
N° 1 - Aluminium tile (5)
N° 1 - Fixed half-shell (6)
N° 1 - Mobile half-shell (7)
The kit includes:
N° 1 - Gasket (1)
N° 1 - Female concentric flange
(2)
N° 1 - Adapter
Ø 80/125 (3)
N° 1 - Concentric intake-exhaust
pipe Ø 80/125 (4)
N° 1 - Wall sealing plate (5)
N° 1 - Aluminium tile (6)
N° 1 - Fixed half-shell (7)
N° 1 - Mobile half-shell (8)
1.13 CONCENTRIC VERTICAL KIT
INSTALLATION.
Type C configuration, sealed chamber and
fan assisted.
Concentric vertical intake and exhaust kit. This
vertical terminal is connected directly to the
outside of the building for air intake and flue
gas exhaust.
NOTE:
the vertical kit with aluminium tile
enables installation on terraces and roofs with
a maximum slope of 45% (approx. 25°) and the
height between the terminal cap and half-shell
(374 mm) must always be observed.
Vertical kit with aluminium tile Ø 60/100.
To use this kit one must use the fixing plate kit
60/100 (sold separately).
Kit assembly (Fig. 1-16): install the concentric
flange (2) on the central hole of the boiler inser-
ting the gasket (1) and tighten using the screws in
the kit. Fit the male end (smooth) of the adapter
(3) into the female end of the concentric flange
(2). Imitation aluminium tile installation. Repla-
ce the tile with the aluminium sheet (5), shaping
it to ensure that rainwater runs off. Position the
fixed half-shell (7) and insert the intake-exhaust
pipe (6). Fit the Ø 80/125 concentric terminal
pipe with the male end (6) (smooth) to the female
end of the adapter (3) (with lip gasket) up to the
end stop; making sure that the wall sealing plate
(4) has been fitted, this will ensure sealing and
joining of the elements making up the kit.
•Extensions for vertical kit Ø 60/100 (Fig. 1-17).
The kit with this configuration can be exten-
ded to
a max. straight vertical length of 4.7 m
,
including the terminal. This configuration
corresponds to a resistance factor of 100. In
this case specific extensions must be requested.
Vertical kit with aluminium tile Ø 80/125.
Kit assembly (Fig. 1-18): to install the kit Ø
80/125 one must use the flanged adapter kit in
order to install the flue system Ø 80/125. Install
the flanged adaptor (2) on the central hole of the
boiler, positioning gasket (1) with the circular
projections downwards in contact with the boiler
flange, and tighten using the screws contained
in the kit. Installation of the fake aluminium
tile: replace the tiles with the aluminium sheet
(4), shaping it to ensure that rainwater runs off.
Position the fixed half-shell (5) on the aluminium
tile and insert the intake-exhaust pipe (7). Fit the
Ø 80/125 concentric terminal pipe with the male
side (smooth) to the female side of the adapter (1)
(with lip gaskets) up to the end stop; making sure
that the wall sealing plate (3) has been fitted, this
will ensure sealing and joining of the elements
making up the kit.
• Extensions for vertical kit Ø 80/125 (Fig. 1-19).
The kit with this configuration can be extended
up to a
max. length of 12.2 m
including the ter-
minal. If additional components are assembled,
the length equivalent to the maximum allowed
must be subtracted. In this case specific exten-
sions must be requested.
MAXIMU
M LEN
GTH 4700 mm
MAXIMU
M LEN
GTH 12200 mm
Summary of Contents for EOLO STAR 24 5E
Page 1: ...EOLO STAR 24 5E IE Instructions and warning book 1 040471ENG ...
Page 2: ......
Page 33: ......
Page 34: ......
Page 35: ......