N.B.:
Pressure values specified in the table indicate the difference of
pressure values between the gas valve outlet and the combustion
chamber. Adjustments are therefore carried out with the differential
pressure gauge ( “U” or digital type) with the sensors inserted in the
test pressure outlet of the modulating adjustable gas valve and on
the sealed chamber positive pressure test outlet. Power data
specified in the table refer to a 0,5 metre intake/exhaust pipe. Gas
flow rates refer to heat power below temperature of 15°C and at a
pressure of 1013 mbar. Burner pressure values refer to use of gas at
15°C.
Flue temperature values refer to air inlet temperatures of 15°C.
Eolo Star variable heat output.
NATURAL GAS (G20)
BUTANE (G30)
PROPANE (G31)
OUTPUT
HEAT
(kcal/h)
OUTPUT
HEAT
(kW)
H
E
A
T
I
N
G
GAS
FLOWRATE
BURNER
(m3/h)
NOZZLES
PRESSURE
BURNER
(mbar) (mm H20)
GAS
FLOWRATE
BURNER
(kg/h)
NOZZLES
PRESSURE
BURNER
(mbar) (mm H20)
GAS
FLOWRATE
BURNER
(kg/h)
NOZZLES
PRESSURE
BURNER
(mbar) (mm H20)
20000
23,3
2,72
10,7
109
2,03
27,7
283
2,00
35,7
364
19000
22,1
2,60
9,8
100
1,94
25,3
258
1,91
32,6
333
18000
20,9
2,47
8,8
90
1,84
22,8
232
1,81
29,4
300
17700
20,6
2,43
8,5
87
1,81
22,1
225
1,78
28,4
290
16000
18,6
2,21
7,0
72
1,65
18,2
186
1,62
23,5
240
15000
17,4
2,08
6,3
64
1,55
16,2
165
1,53
20,9
213
14000
16,3
1,96
5,5
56
1,46
14,3
146
1,44
18,4
188
13000
15,1
1,83
4,8
49
1,36
12,5
128
1,34
16,1
164
12000
14,0
1,70
4,2
43
1,27
10,8
111
1,25
14,0
143
11000
12,8
1,58
3,6
37
1,17
9,3
95
1,16
12,0
122
10000
11,6
1,45
3,0
31
1,08
7,9
80
1,06
10,1
103
9000
10,5
1,32
2,5
26
0,98
6,5
67
0,97
8,4
86
8000
9,3
1,19
2,3
23
0,89
5,6
57
0,87
7,2
73
6000
7,0
Domestic
0,88
1,1
11
0,65
3,0
31
1,06
3,6
37
Eolo Star technical specifications.
Nominal heating capacity
Min. heating capacity
Nominal heat output (useful)
Min. heat output (useful)
Useful heating efficiency at nominal output
Useful heating efficiency at 30% nom. output
Heat loss at shell with burner On/Off
Heat loss at flue with burner On/Off
kW (kcal/h)
kW (kcal/h)
kW (kcal/h)
kW (kcal/h)
%
%
%
%
25,7 (22124)
11,2 (9674)
23,3 (20000)
9,3 (8000)
90,4
88,5
2,1/0,53
7,5/0,02
G20
G30
G31
Diam. nozzles
Feed pressure
mm
mbar (mm H
2
O)
1,30
20 (204)
0,77
29 (296)
0,77
37 (377)
Max. working pressure heating circuit
Max. working temp. heating circuit
Adjustable temp. heating
Total volume expansion tank
Expansion tank precharge
Water content of generator
Available head with flowrate 1000 l/h
Useful heat output hot water production
Domestic hot water adjustable temp.
Flow limiter
Min. pressure (dynamic) domestic circuit
Max. working pressure domestic circuit
Min. drawing domestic hot water
Drawing capacity in continuous service (∆T 30 deg. C)
Specific capacity (∆T 30 deg. C)
Min. pressure for flow limiter capacity
Weight of boiler full
Weight of boiler empty
bar
°C
°C
l
bar
l
kPa (m H
2
O)
kW (kcal/h)
°C
l/min
bar
bar
l/min
l/min
l/min
bar
kg
kg
3
90
35 - 80
6
1,0
3,5
23,03 (2,35)
23,3 (20000)
35 - 55
8
0,26
10
2,5
11,1
10,7
1
38
34
Electrical connection
Nominal absorption
Installed electrical power
Power absorbed by circulating pump
Power absorbed by fan
Appliance electrical system protection
V/Hz
A
W
W
W
-
230/50
0,8
140
63
46
IPX4D
G20
G30
G31
Fumes flowrate in mass at nominal output
Fumes flowrate in mass at min. output
CO
2
at Nom./Min. Q.
CO at 0% O
2
at Nom./Min. Q.
NO
x
at 0% O
2
at Nom./Min. Q.
Fumes temp. at nom. output
Fumes. temp. at min. output.
kg/h
kg/h
%
ppm
ppm
°C
°C
58
61
6,3/2,5
58/70
68/50
122
100
56
61
7,6/2,9
115/85
226/134
122
101
56
61
7,5/2,9
66/79
200/103
123
100