13
Inoxstor Pre-Plumbed Water Heater
Installation, Usage and Maintenance Instructions
Menu Tree
Set to
Menu
Lingua
Eng
Menu
Service
Definition of Zone
Room Control Switch
T.A.
Menu
Service
Definition of Zone
Mode Control
External
Menu
Service
Defining Plant
External Probe
PdC
Menu
Service
Defining Plant
Enabling DHW
Yes
Menu
Service
Thermoreg. Parameters
Modulation with room probe
No
Menu
Service
Thermoreg. Heat
Adjust weather compensation curve
if required.
Menu
Set point DHW
Set Comfort to 50°C.
Menu
Time and Program
Date and Time
Set Date & Time
Menu
Time and Program
Time Slots
1
Create on period from 00:00 to 24:00
Menu
Time and Program
DHW Program
Monday - Sunday
Use time slot 1
7.3 CHECKING THE OPERATION OF SAFETY VALVES
Manually operate the valve lever on the Pressure Relief Valve for a few seconds. Check that water is discharged and that it
flows freely through the tundish and discharge pipework. Check that the valve reseats correctly when released.
Repeat the procedure for the Temperature & Relief Valve, if installed. Note: The water discharged may be very hot.
7.4 FILLING THE AUDAX AND CENTRAL HEATING SYSTEM
Follow the Immergas Audax Instructions, "Installation of the Unit" section. Ensure that water quality guidelines are fol-
lowed.
7.5 ANNUAL MAINTENANCE
The Inoxstor should be inspected and serviced annually. As a minimum, check operation of both pressure relief valve and
T&P valve (if installed), check system for leaks, check expansion vessel and check operation of immersion thermostat.
Important: After servicing, preliminary electrical system checks must be carried out to ensure electrical safety (i.e. polarity,
earth continuity, resistance to earth and short circuit).
Annual maintenance of the Immergas Audax Heat Pump should be carried out as specified in the Immergas Audax Heat
Pump instructions.
8. AUDAX - SUGGESTED SETTINGS
The following is a quick reference for settings to use when commissioning the Audax heat pump.
These suggested settings will configure the Audax to use external timeclocks, Weather Compensation, and enable DHW
with a set point of 50°C. These settings will ensure compatibility with the Inoxstor Pre-Plumbed Water heater.
Summary of Contents for INOXSTOR 200
Page 16: ...11 DECLARATION OF CONFORMITY ...
Page 17: ......