9
Inoxstor Pre-Plumbed Water Heater
Installation, Usage and Maintenance Instructions
4.2 AUDAX CONTROL WIRING
The Inoxstor is pre-wired and configured for use with two heating zones in addition to the provision of hot water.
On the Inoxstor, the following is pre-wired:
▪
Audax Remote Controller
▪
Zone valves - Zone 1 and 2
▪
Three way valve
▪
Hot Water Sensor
▪
Anti-legionella timer and Immersion
Connect the Audax interface board on the Inoxstor to the Audax using three no cables:
• 2 no 4x0.75mm
2
minimum (screened)
• 1 no 1x0.75mm
2
minimum
Connect these cables as shown in the diagram below.
Important -
It is necessary to connect terminals no. 5 and no. 13 on the Audax together.
If these are not
connected, the heat pump will run in cooling mode.
Core
Audax Control Board Terminal
Audax Terminal
Cable 1
(Low Voltage)
Screened
Min 4x0.75mm2
1
4
4
2
13
13
3
14
14
4
18
18
Cable 2 (230V)
Min 1x0.75mm2
1
19
19
Cable 3
(Low Voltage)
Screened
Min 4x0.75mm2
1
24
24
2
25
25
3
34
34
4
36
36