21 : 10
22°C P-1
spento
14 : 35
22°C P-1
fuoco
presente
14 : 35
21°C P-2
ACCENDE
14 : 35
21°C P-2
carica
pellet
15 : 18
22°C P-3
lavoro
15 : 18
22°C p-2
pulizia
braciere
33
Installation
First ignition may also fail since the auger is empty and does not always manage to load the necessary amount of pellets
in the brazier in time for regular ignition of the flame.
If this should occur, CANCEL THE TRIGGERED FAILED IGNITION ALARM. REMOVE THE PELLETS LEFT IN THE
BRAZIER AND REPEAT IGNITION.
It is good practice to ensure the technical room is well ventilated during initial ignition since the boiler emits a bit of
smoke and smell of paint.
INFORMATION ON DISPLAY
SPENTO - (OFF)
The Boiler is off.
ACCENDE - (ON)
The boiler is in the first ignition phase.
The glow plug and flue gas extractor are active.
CARICA PELLET - (PELLET LOADING)
At this stage of the ignition process the boiler starts loading pellets into the brazier.
The glow plug, flue gas extractor and auger motor are active.
FUOCO PRESENTE - (FIRE PRESENT)
At this stage of the ignition process the boiler starts loading pellets into the brazier.
Flue gas extractor and auger motor are active.
PULIZIA BRACIERE - (BRAZIER CLEANING)
The boiler is cleaning the brazier.
The flue gas extractor runs at maximum speed and the pellet loading is at minimum.
Every 60 minutes of boiler operation, cleaning is carried out automatically for 30 seconds
LAVORO - (OPERATION)
The boiler is in operation, in this case at power 3.
The detected room temperature is 21°C. During normal operation the flue gas fan, auger motor and
room fan are active.