The kit includes:
N° 1 - Gasket (1)
N° 1 - Concentric bend Ø 60/100 (2)
N° 1 - Int./exhaust concentric terminal Ø 60/100 (3)
N° 1 - Internal ring (4)
N° 1 - External ring (5)
The adaptor kit includes:
N° 1 - Gasket (1)
N° 1 - Adaptor Ø 80/125 (2)
1.11 CONCENTRIC HORIZONTAL KIT
INSTALLATION.
Type C configuration, sealed chamber and
fan assisted.
Horizontal intake - exhaust kit Ø60/100.
Kit
assembly (Fig. 1-11): install the bend with flange
(2) on the central hole of the boiler, positioning
the gasket (1)
(which does not require lubrication)
positioning it with the circular projections
downwards in contact with the boiler flange
and tighten using the screws present in the kit.
Fit the Ø 60/100 (3) concentric terminal pipe
with the male end (smooth) to the female end
of the bend (2) up to the stop; making sure that
the internal and external wall sealing plate have
been fitted, this will ensure sealing and joining
of the elements making up the kit.
• Extensions for Ø 60/100 horizontal kit (Fig.
1-12). The kit with this configuration can
be extended up to a
max. 12.9 horizontal m
including the terminal with grid and excluding
the concentric bend leaving the boiler. This
configuration corresponds to a resistance factor
of 100. In this case the special extensions must
be requested.
• External grid.
N.B.:
for proper system
operation the terminal with grid must be
installed correctly ensuring that, the "high"
indication on the terminal is observed during
installation.
Horizontal intake - exhaust kits Ø80/125.
Kit
assembly (Fig. 1-13): to install the kit Ø 80/125
one must use the flanged adapter kit in order
to install the flue system Ø 80/125. Install the
flanged adaptor (2) on the central hole of the
boiler, positioning the gasket (1)
(which does not
require lubrication)
with the circular projections
downwards, in contact with the boiler flange and
tighten using the screws contained in the kit.
Engage the bend (3) with the male side (smooth)
until it is fully home on the adapter (1). Fit the Ø
80/125 (5) concentric terminal pipe with the male
end (smooth) to the female end of the bend (4)
(with lip seals) up to the stop; making sure that
the internal (6) and external wall sealing plates
(7) have been fitted, this will ensure sealing and
joining of the elements making up the kit.
• Extensions for horizontal kit Ø 80/125 (Fig.
1-14). The kit with this configuration can
be extended up to a
max. length of 32 m
,
including the terminal with grid and excluding
the concentric bend leaving the boiler. If
additional components are assembled, the
length equivalent to the maximum allowed
must be subtracted. In this case the special
extensions must be requested.
The Kit Ø 80/125 includes:
N° 1 - Concentric bend Ø
80/125 a 87° (3)
N° 1 - Int./exhaust concentric
terminal Ø 80/125 (4)
N° 1 - Internal ring (5)
N° 1 - External ring (6)
The remaining kit components
must not be used