The kit includes:
N° 1 - Exhaust gasket (1)
N° 1 - Flange seal gasket (2)
N° 1 - Female intake flange (3)
N° 1 - Female drain flange (4)
N° 2 - Bend 90° Ø 80 (5)
N° 1 - Intake terminal Ø 80 (6)
N° 2 - Internal rings (7)
N° 1 - External ring (8)
N° 1 - Drain pipe Ø 80 (9)
1.13 SEPARATOR KIT INSTALLATION.
Type C configuration, sealed chamber and
fan assisted.
Separator kit Ø 80/80.
This kit allows air to come
in from outside the building and the fumes to
exit from the chimney or flue through divided
flue exhaust and air intake pipes. Combustion
products are expelled from pipe (S) (in plastic,
so as to resist acid condensate). Air is taken in
through duct (A) for combustion (this is also
in plastic). The intake pipe (A) can be installed
either on the right or left hand side of the central
exhaust pipe (S). Both ducts can be routed in
any direction.
• Kit assembly (Fig. 1-19): install the flange (4)
on the central hole of the boiler, positioning the
gasket (1)
(which does not require lubrication)
positioning it with the circular projections
downwards in contact with the boiler flange
and tighten using the hex screws with flat tip
contained in the kit. Remove the flat flange
present in the lateral hole with respect to the
central one (according to needs) and replace it
with the flange (3), positioning the gasket (2)
already present in the boiler and tighten using
the supplied self-threading screws. Fit the male
end (smooth) to the bends (5) in the female end
of the flanges (3 and 4). Fit the intake terminal
(6) with the male section (smooth) in the
female section of the bend (5) up to the stop,
ensuring that the internal and external wall
sealing plates are fitted. Fit the exhaust pipe
(9) with the male end (smooth) to the female
end of the bend (5) up to the stop; making sure
that the internal wall sealing plate has been
fitted, this will ensure sealing and joining of
the elements making up the kit.
• Installation clearances (Fig. 1-20). The
minimum installation clearance measurements
of the Ø 80/80 separator terminal kit have been
stated in some limit conditions.
• Extensions for separator kit Ø 80/80. The
maximum vertical straight length (without
bends) that can be used for Ø 80 intake and
exhaust pipes is 41 metres, regardless from
whether they are used for intake or exhaust.
The maximum horizontal straight length (with
bend in suction and in exhaust) that can be
used for Ø 80 intake and exhaust pipes is 36
metres, regardless from whether they are used
for intake or exhaust.
N.B.:
to favour the removal of possible
condensate forming in the exhaust pipe, tilt the
pipes towards the boiler with a minimum slope
of 1.5% (Fig. 1-21).
Minimum slope 1.5%