Kit composition:
Ref.
Qty
Description
1
1
Door adaptor Ø 100 or Ø 125
2
1
Door gasket made of neoprene
3
4
Screws 4.2 x 9 AF
4
1
Screw TE M6 x 20
5
1
Flat nylon washer M6
6
2
Door hole closure sheet metal plug
7
1
Plug gasket made of neoprene
8
1
Toothed washer M6
9
1
Nut M6
10 1 (kit 80/125) Concentric gasket Ø 60-100
11 1 (kit 80/125) Flanged adapter Ø 80-125)
12 4 (kit 80/125) Screws TE M4 x 16 slotted
-
1 (kit 80/125) Bag of lubricating talc
Supplied separately:
Installation drawings key:
Unique identification of the component in
the kit
Identification of the component not supplied
in this kit
1
A
Ref. Qty Description
A
1
Ducting kit door
Rigid Ø 80
piping
(A) mm
SHAFT
(B) mm
SHAFT
(C) mm
86
126
146
Flexible Ø 80
piping
(A) mm
SHAFT
(B) mm
SHAFT
(C) mm
90
130
150
Rigid Ø 60
piping
(A) mm
SHAFT
(B) mm
SHAFT
(C) mm
66
106
126
1.14 ADAPTOR C9 KIT INSTALLATION.
This kit allows to install an Immergas boiler in
configuration "C93", achieving the combustion
air intake directly from the shaft featuring the
fumes exhaust, obtained by means of a ducting
system.
System composition.
The system must be combined with the following
components (sold separately) to be functional
and complete:
- kit C93 version Ø 100 or Ø125;
- ducting kit Ø 60 o Ø 80;
- fumes exhaust kit Ø60/100 or Ø 80/125
configured according to the installation and
type of boiler.
Kit Assembly.
- Mount the components of kit "C9" on the door
(A) of the ducting system (Fig. 1-23).
- (Version Ø 125 only) mount the flanged
adaptor (11) interposing the concentric gasket
(10) on the boiler, fitting it with the screws (12).
- Mount the ducting system as described in the
relative instructions sheet.
- Calculate the distances between the boiler drain
and the bend of the ducting system.
- Prepare the boiler flue system, making sure that
the internal pipe of the concentric kit is fitted
properly in the bend of the ducting system
(quota "X" fig. 1-24), while the external pipe
must be fitted on the adaptor until it stops (1).
N.B.:
to encourage the removal of possible
condensate forming in the exhaust pipe, tilt
the pipes towards the boiler with a minimum
slope of 1.5%.
- Mount the cover (A) complete with adaptor (1)
and caps (6) on the wall and assemble the flue
system to the ducting system.
N.B.:
(version Ø 125 only) before assembly check
the gaskets are in the right position. In the event
component lubrication (already carried out
by the manufacturer) is not sufficient, remove
the residual lubricant using a dry cloth, then
to ease fitting coat the parts with common or
industrial talc.
Once all components have been assembled
properly, the exhaust fumes will be expelled
via the ducting system; the combustion air for
normal boiler operation will be aspirated directly
by the shaft (Fig. 1-24).
Technical data.
- The dimensions of the shafts must ensure a
minimum gap between the outer wall of the
smoke duct and the inner wall of the shaft: 30
mm for circular section shafts and 20 mm in
the event of a square section shaft (Fig. 1-22).
- Maximum 2 changes of direction are allowed
on the vertical section of the flue system with
a maximum clearance angle of 30° with respect
to the vertical.
- The maximum vertical extension using a Ø
60 ducting system is 13 m, the maximum
extension includes 1 bend Ø 60/10 at 90°, 1 m
of horizontal pipe 60/100, 1 90° ducted bend
Ø 60 and the roof terminal for ducting.
To determine the C93 flue system in
configurations other than that described (Fig.
1-24) one must consider that 1 metre of ducted
pipe according to the indications described has
a resistance factor equal to 4.9.
- The maximum vertical extension using a Ø
80 ducting system is 28 m, the maximum
extension includes 1 adapter 60/100 to 80/125,
1 87° bend Ø 80/125, 1 m of horizontal pipe
80/125, 1 90° ducted bend Ø 80 and the roof
terminal for ducting.
To determine the C93 flue system in
configurations other than that described (Fig.
1-24) one must consider the following pressure
drops:
- 1 m of concentric pipe Ø 80/125 = 1 m of
ducted pipe;
- 1 87° bend = 1.4 m of ducted pipe.
Consequently one must subtract the equivalent
length of the part added to the 28 m available.