27 - IE
INS
TALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
AN
1
st
Level Button
2
nd
Level
Button
3
rd
Level
Button
Description
M1
D
C
P11
D
C
View the management software version of the P.C.B. installed in the boiler.
P12.
View the total functioning hours of the boiler.
P13
View the number of burner ignitions.
P14
(with optional
external probe
present)
- - -
(without external
probe (optional)
D
C
P14/A
View the current external temperature (if optional external probe present).
P14/B
View the minimum external temperature recorded (if optional external
probe present).
P14/C
View the maximum external temperature recorded (if optional external
probe present).
RESET
D
x
select
C
By pressing button "D" the MIN and MAX temperatures measured are
reset to zero.
P15
D
C
View the value of the domestic hot water flow rate from the flow meter.
P17
View the fan instantaneous rotation percentage speed (in RPM).
P18
View the circulator pump instantaneous speed (in %).
P19
View the last 5 events that caused boiler shutdown. Indicator (6) shows the
sequential number from 1 to 5 and on indicator (7) the relative error code.
By pressing button "D" repeatedly it is possible to view the functioning
time and the number of ignitions at which the anomaly occurred.
Information Menu.
This menu contains the various information relative to boiler functioning:
1
st
Level Button 2
nd
Level
Button
3
rd
Level
Button
4
th
Level
Button
Description
M3
D
C
P31
D
C
AUTO
(Default)
D
x
select
C
The display lights up when the burner is ignited
and when the controls are accessed, it remains on
for 5 seconds after the last operation performed.
ON
The display is always lit up.
OFF
The display only lights up when the controls are
accessed and remains on for 5 seconds after the
last operation performed.
P32
D
C
P32/B
D
C
ITALIANO
(Default)
D
x
select
C
All descriptions are given in Italian.
A-1
All descriptions are given in alphanumerical
format.
P33
D
C
OFF
(Default)
D
x
select
C
In winter mode, by activating this function it is
possible to activate the room heating function
even if the eventual Remote Control or TA are
out of service.
ON
RESET
D
x
select
C
By pressing button “D” the customisations made
are reset, restoring the default values of “P31” in
“ILL. AUTO” and “P32/B” in “ITALIANO”.
Customisation menu.
This menu contains all
functioning options that can be customised.
(The first item of the various options that appears
inside the parameter is that selected by default).
Attention:
to view the information in the
international language (
A-1
) one must proceed
as follows:
2.7 PARAMETERS AND INFORMATION
MENU.
By pressing the button "D" it is possible to access
a menu divided into three main parts:
- “M1” information.
- “M3” customisations.
- “M5” configurations, menu reserved to the
technician and for which a password is required
(See “Technician” chapter).
By turning the heating temperature selector
switch (3) scroll through the menu items. By
pressing button “D” access the various levels
of the menu and the choice of parameters is
confirmed. Press button “C” to go back one level.
- press button "D" to enter the configuration
menu.
- turn selector switch "3" to
“PERSONAL”
.
- press button "D" to confirm.
- turn selector switch "3" to
“DATI”
.
- press button "D" to confirm.
- turn selector switch "3" to
“LINGUA”
.
- press button "D" to confirm.
- turn selector switch "3" to
“A-1”
.
- press button "D" to confirm.
At this point the international items indicated in
the menu tables appear on the display.
Summary of Contents for MAGIS Victrix
Page 1: ...MAGIS Victrix IE Instruction and warning book 1 035518ENG ...
Page 2: ......
Page 42: ......
Page 43: ......