3.22 TECHNICAL DATA.
- The fumes temperature values refer to the inlet
air temperature of 15°C and flow temperature
of 50° C.
- The data relating to the domestic hot water
efficiency refer to a dynamic inlet pressure of
2 bar and to an inlet temperature of 15°C; the
values are detected immediately at boiler outlet,
considering that to achieve the declared data,
mixing with cold water is required.
- The maximum sound level emitted during
boiler operation is < 55dBA. The measured
sound level value is referred to semianechoic
chamber tests with boiler operating at max.
heat output, with extension of flue gas exhaust
system according to product standards.
- * Specific flow rate “D”: domestic hot water
flow rate corresponding to an average increase
in temperature of 30 K, which the boiler can
provide in two subsequent collections.
Domestic hot water nominal heat input
kW (kcal/h)
26.7 (22980)
Central heating nominal heat input
kW (kcal/h)
24.1 (20738)
Minimum heat input
kW (kcal/h)
3.3 (2815)
Domestic hot water nominal heat output (useful)
kW (kcal/h)
26.0 (22360)
Central heating nominal heat output (useful)
kW (kcal/h)
23.6 (20296)
Minimum heat output (useful)
kW (kcal/h)
3.0 (2580)
Efficiency 80/60 Nom./Min.
%
97.9 / 91.6
Efficiency 50/30 Nom./Min.
%
106.0 / 103.7
Efficiency 40/30 Nom./Min.
%
107.0 / 104.7
Heat loss at casing with burner On/Off (80-60°C)
%
0.61 / 0.80
Heat loss at flue with burner On/Off (80-60°C)
%
0.04 / 1.90
Central heating circuit max. operating pressure
bar
3
Central heating circuit max. operating temperature
°C
90
Adjustable heating temperature (max operation field)
°C
20 - 85
System expansion vessel total volume
l
5.8
Expansion vessel factory-set pressure
bar
1.0
Water content in generator
l
4.46
Head available with 1000 l/h flow rate
kPa (m H
2
O)
55.8 (5.69)
Hot water production useful heat output
kW (kcal/h)
26.0 (22360)
Domestic hot water adjustable temperature
°C
30 - 60
Domestic hot water flow limiter
l/min
Automatic
Domestic circuit min. pressure (dynamic)
bar
0.3
Domestic hot water circuit max. working pressure
bar
10
*Specific capacity “D” according to EN 625
l/min
13.4
Flow rate capacity in continuous duty (∆T 30°C)
l/min
13.3
Domestic hot water performance classification according to N 13203-1
Weight of full boiler
kg
48.96
Weight of empty boiler
kg
44.5
Electrical connection
V/Hz
230 / 50
Nominal absorption
A
1.0
Installed electric output
W
150
Pump consumption
W
48
Fan power consumption
W
22
Equipment electrical system protection
-
IPX5D
Max temperature of combustion products
°C
75
NO
X
class
-
5
Weighted NO
X
mg/kWh
26
Weighted CO
mg/kWh
15
Type of appliance
C13 / C33 / C43 / C53 / C83 / C93 / B53p / B33
Category
II 2H3P