27
3-4
a
1
1
3
3
2
a
b
b
c
INS
TALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
AN
3.16 CASING REMOVAL.
To facilitate boiler maintenance the casing can be
completely removed as follows (Fig. 3-4 / 3-5):
1 Unhook the decorative frame (a) from the
relative lower retainers.
2 Remove the decorative frame (a) from the
casing (c).
3 Loosen the 2 front screws (b) for fixing the
casing.
4 Loosen the 2 lower screws (b) for fixing the
casing.
5 Pull the case towards yourself (c).
6 Push the case (c) upwards at the same time to
release it from the upper hooks.
Installation drawings key:
Unmistakeable component identification
Sequential identification of the operation to perform
Summary of Contents for MINI EOLO 28 3E
Page 1: ...MINI EOLO 28 3E Instruction and warning booklet IE 1 038767ENG ...
Page 2: ......
Page 28: ...28 3 5 4 4 5 6 6 d d c INSTALLER USER MAINTENANCE TECHNICIAN ...
Page 32: ...32 ...
Page 33: ...33 ...
Page 34: ...34 ...
Page 35: ...35 ...