When installing horizontal pipes, a minimum inclina-
tion of 1.5% towards the boiler must be maintained, and
a section clip with pin must be installed every 3 metres.
Installation inside the recessed frame
In this mode, install the flue according to your needs using the ap-
propriate pre-sections in the frame to exit from its clearances.
Diaphragm installation
For correct functioning of the boiler it is necessary to install a
diaphragm on the outlet of the sealed chamber and before the in-
take and exhaust pipe.
The appropriate diaphragm is chosen based on type of pipe and its
maximum extension: this calculation can be made using the
tables below:
The diaphragms are supplied together with the boiler as
standard.
1
2
3
4
11
Key (Fig. 11):
1 - Concentric flue intake diaphragm Ø 80
2 - Concentric flue intake diaphragm Ø 77
3 - Divided flue intake diaphragm Ø 45
4 - Divided flue intake diaphragm Ø 55
Diaphragm
Pipe extension in metres Ø
60/100 horizontal
Ø80 (Ref. 1)
From 0.35 to 0.5
Ø 77 (ref. 2)
From 0.5 to 1.5
Without
From 1.5 to 3
Diaphragm
Pipe extension in metres Ø
60/100 vertical
Ø80 (Ref. 1)
From 0.35 to 1.8
Ø 77 (ref. 2)
From 1.8 to 2.8
Without
From 2.8 to 4.3
Diaphragm
Pipe extension in metres Ø
80/125 horizontal
Ø80 (Ref. 1)
From 0.35 to 4.2
Ø 77 (ref. 2)
from 4.2 to 6.9
Without
From 6,9 to 11,6
Diaphragm
Pipe extension in metres Ø
80/125 vertical
Ø80 (Ref. 1)
From 0.35 to 8.5
Ø 77 (ref. 2)
From 8.5 to 11.3
Without
From 11.3 to 16
Diaphragm
(*) Duct length in metres
Ø80 horizontal with two bends
Exhaust
Intake
-
Ø 45 (ref. 3)
from 0 to 7
-
Ø 55 (ref. 4)
From 7 to 27
Diaphragm
(**) Duct length in metres
Ø80 horizontal with two bends
Exhaust
Intake
-
Ø 45 (ref. 3)
from 0 to 7
-
Ø 55 (ref. 4)
From 7 to 35
Diaphragm
(*) Duct length in metres
Ø80 vertical without bends
Exhaust
Intake
-
Ø 45 (ref. 3)
From 0 to 10
-
Ø 55 (ref. 4)
From 10 to 30
Diaphragm
(**) Duct length in metres
Ø80 vertical without bends
Exhaust
Intake
-
Ø 45 (ref. 3)
From 0 to 12
-
Ø 55 (ref. 4)
From 12 to 40
Diaphragm
(**) Duct length in metres
Ø80 flexible vertical with two
bends
Exhaust
Intake
-
Ø 45 (ref. 3)
From 0 to 3.4
-
Ø 55 (ref. 4)
From 3.4 to 6.7
(**) These maximum extension values are considered exhaust
with 1 metre intake pipe.
(**) These maximum extension values are considered intake with
1 metre exhaust pipe.