2.6 INFORMATION MENU
Pressing the buttons “ and “ simultaneously for 5 seconds, the
“Information menu” is activated, which displays some boiler fun-
ctioning parameters.
Press buttons “ ” and “ ” to scroll through the various parame-
ters.
To exit the menu, press buttons “ ” e “ ” simultaneously again
for 5 seconds or wait for 5 minutes.
Parameter ID
Description
d 0.1
Displays the flame signal
d 0.2
Displays the primary exchanger output instant heating flow temperature (flow probe)
d 0.3
Displays the instant output temperature from the DHW exchanger
d 0.4
Displays the fan operating speed (rpm x 100)
d 0.5
Displays the operating instantaneous power (value in %)
d 0.6
Displays the temperature set for the central heating set (if remote control is present)
d 0.7
Displays the temperature set for the DHW set (if remote control is present)
E1 - E8
Display the anomaly history, of which E1 is the most recent
2.7 RESETTING THE ANOMALY HISTORY
Press the “
” button on the information menu for > 2 seconds
and < 5 seconds.
The display will show "E-": at this point release the "
" key.