41
4.2 COMBUSTION PARAMETERS.
G20
Supply pressure
mbar (
mm H
2
O
)
20 (204)
Gas nozzle diameter
mm
0.85
Flue flow rate at nominal heat output
kg/h (g/s)
71 (19.72)
Flue flow rate at min DHW / heat output
kg/h (g/s)
52 (14.44) / 54 (15.00)
CO
2
at Nom./Min. DHW/Min. Heat. Q.
%
5.30 / 2.50 / 2.70
(± 0.2)
CO with 0% O
2
at Nom./Min. Q.
ppm
108 / 26
NO
X
with 0% O
2
at Nom./Min. Q.
mg/kWh
113 / 29
Flue temperature at nominal output
°C
96
Flue temperature at minimum output
°C
61
4
TECHNICAL DATA.
4.1 VARIABLE HEAT OUTPUT.
N.B.:
the power data in the table have been obtained with in-
take-exhaust pipe measuring 0.5 m in length. Gas flow rates refer
to net calorific value at a temperature of 15°C and at a pressure
of 1013 mbar. Burner pressure values refer to use of gas at 15°C.
Combustion parameters: measuring conditions of useful efficien-
cy (flow temperature/return temperature= 80 / 60 °C), ambient
temperature reference = 15°C.
METHANE (G20)
HEAT
THERMAL
HEAT
THERMAL
GAS FLOW RATE
BURNER
PRESS. NOZZLE
BURNER
(kW)
(kcal/h)
(m
3
/h)
(mbar)
(
mm H
2
O
)
MAX. OUTPUT
24.0
20640
2.82
12.6
128.5
MIN CH.
9.5
8170
1.13
2.4
24.5
MIN. DHW
8.5
7310
1.02
2.1
21.4