4.3 TECHNICAL DATA TABLE
Domestic hot water nominal heat input
kW (kcal/h)
25.7 (22119)
Central heating nominal heat input
kW (kcal/h)
20.8 (17885)
Minimum heat input
kW (kcal/h)
4.2 (3626)
Domestic hot water nominal heat output (useful)
kW (kcal/h)
25 (21500)
Central heating nominal heat output (useful)
kW (kcal/h)
20.2 (17372)
Minimum heat output (useful)
kW (kcal/h)
4 (3440)
*Effective thermal efficiency 80/60 Nom./Min.
%
97.1 / 94.9
*Effective thermal efficiency 50/30 Nom./Min.
%
105 / 105.8
*Effective thermal efficiency 40/30 Nom./Min.
%
106.9 / 107,7
Casing losses with burner On/Off (80-60°C)
%
0,38 / 0,05
Chimney losses with burner On/Off (80-60°C)
%
0,02 / 2,75
Central heating circuit max. operating pressure
bar (MPa)
3,0 (0,30)
Maximum heating temperature
°C
90
Adjustable central heating temperature (min. operating field)
°C
20-50
Adjustable central heating temperature (max operating field)
°C
55-85
System expansion vessel total volume
l
5.8
Expansion vessel pre-charged pressure
bar (MPa)
1,0 (0,10)
Appliance water content
l
2
Head available with 1000 l/h flow rate
kPa (m H
2
O)
26,7 (2,7)
Hot water production useful heat output
kW (kcal/h)
25 (21500)
Domestic hot water adjustable temperature
°C
20-60
Domestic hot water circuit min. pressure (dynamic)
bar (MPa)
0,3 (0,03)
Domestic hot water circuit max. operating pressure
bar (MPa)
10,0 (1,00)
Flow rate capacity in continuous duty (∆T 30°C)
l/min
12.5
Weight of full boiler
kg
31
Weight of empty boiler
kg
29
Electrical connection
V~ / Hz
230 / 50
Nominal power absorption
A
0.67
Installed electric power
W
90
Pump absorbed power
W
40
EEI value
-
≤ 0.20 - Part. 3
Fan power absorbed power
W
87.9
Equipment electrical system protection
-
IPX5D
Max temperature of combustion products
°C
75
Max. flue overheating temperature
°C
120
Ambient operating temperature range
°C
-5 ÷ +40
Ambient operating temperature range with optional antifreeze kit
°C
-15 ÷ 40
NO
X
class
-
6
*Weighted NO
X
mg/kWh
36
Weighted CO
mg/kWh
23
**Type of appliance
-
C13-C13x-C33-C33x-C43-
C43x-C53-C63-C83-C93-
C93x B23-B53p
Market
-
IE
Category
-
II 2H3P
The data relevant to domestic hot water performance refer to a dynamic inlet pressure of 2 bar and an inlet temperature of 15°C; the values
are measured directly at the appliance outlet considering that to obtain the data declared mixing with cold water is necessary.
* Efficiencies and weighted NOx refer to the net calorific value.
** For type C63 it is forbidden to install the appliance as it came out of the factory, in configurations that require shared flues in positive
pressure.