8
1-3
1-4
Attention:
Immergas declines all liability in the
event of damage caused by the inclusion of auto-
matic filling that is not its own brand.
In order to meet the system requirements es-
tablished by EN 1717 and in observance of local
technical regulations in force on the pollution
of drinking water, we recommend installing
an anti-backflow kit to be used upstream of
the cold water inlet connection of the boiler.
We also recommend using a category 1, 2 or
3 heat transfer fluid (ex: water + glycol) in the
boiler’s primary circuit (CH circuit), as defined
in standard EN 1717.
Attention:
to preserve the duration of appliance
efficiency features, we recommend the installation
of a suitable device for water treatment in presence
of water whose characteristics can lead to the
deposit of lime scale.
Condensate drain.
To drain the condensate
produced by the appliance, it is necessary to
connect to the drainage system by means of
acid condensate resistant pipes, with an internal
Ø of at least 13 mm. The system connecting the
appliance to the drainage system must be carried
out in such a way as to prevent freezing of the
liquid contained in it. Before appliance ignition,
ensure that the condensate can be correctly re-
moved. After first ignition, check that the drain
trap is filled with condensate (para. 1.21). Also,
comply with national and local regulations on
discharging waste waters.
In the event condensate is not discharged into
the wastewater drainage system, a condensate
neutraliser must be installed to ensure com-
pliance with the parameters established by the
legislation in force.
1.9 ELECTRIC CONNECTION.
The operations described below must be performed
after after having disconnected the electrical supply
from the appliance.
The electrical system must be built in compliance
with technical standards and all legislation in
force. The boiler has an IPX5D protection rating
for the entire appliance. Electrical safety of the
appliance is reached only when it is correctly
connected to an efficient earthing system as
specified by current safety standards.
Attention:
Immergas S.p.A. declines any respon-
sibility for damage or physical injury caused by
failure to connect the boiler to an efficient earth
system or failure to comply with the reference
standards.
Also ensure that the electrical installation corre-
sponds to maximum absorbed power specifica-
tions as shown on the boiler data-plate.
Boilers are supplied complete with an “X” type
power cable without plug. The power supply
cable must be connected to a 230V ±10% /
50Hz mains supply respecting L-N polarity and
earth connection;
, this network must also
have a multi-pole circuit breaker with class III
over-voltage category.
The main switch must be installed outside
the rooms in a position that is indicated and
accessible.
When replacing the power supply cable, contact a
qualified company (e.g. the Immergas Authorised
After-Sales Technical Assistance Service). The
power cable must be laid as shown (Fig. 1-3).
In the event of mains fuse replacement on the
connection terminal board, use a 3.15A fast fuse.
For the main power supply to the appliance,
never use adapters, multiple sockets or exten-
sion leads.
Important:
if the Digital Remote Control is
used, arrange two separate lines in compliance
with current regulations regarding electrical sys-
tems. No boiler pipes must ever be used to earth
the electric system or telephone lines. Ensure
elimination of this risk before making the boiler
electrical connections.
•
Low temperature system installation.
The
boiler can directly supply a low temperature
system, limiting the value of the “P02” pa-
rameter, which defines the generator’s flow
temperature. In this situation it is good practice
to insert a safety device in series with the power
supply and boiler. This device is made up from
a thermostat with a temperature limit of 55
°C. The thermostat must be positioned on the
system flow pipe at a distance of over 2 metres
from the boiler.
Supply
cable
EXTERNAL RELAY
(OPTIONAL)
230 Vac
50Hz
230 Vac COIL
MAX 0.1 A
ALARM
FREE CONTACTS
MAX 1 A. 230 Vac
External reset
230 Vac
ANALOGUE
INPUT