VICTRIX ZEUS Superior kW I
Technical Documentation
Technical Documentation
Fault and anomaly signals.
6
Anomaly signalled
Error code display
Super CAR display
Car display
No ignition block
ERR 01
ERR 01
E01
Safety thermostat block (over-heating), flame
control anomaly
ERR 02
ERR 02
E02
Flue safety thermostat block
ERR 03
ERR 03
E02 + E03
Contacts resistance block
ERR 04
ERR 04
E02 + E04
Flow probe anomaly
ERR 05
ERR 05
E05
Insufficient system pressure
ERR 10
ERR 10
E10
Domestic hot water probe anomaly
ERR 12
ERR 12
E12
Configuration error
ERR 15
ERR 15
E15
Fan anomaly
ERR 16
ERR 16
E16
Parasite flame block
ERR 20
ERR 20
E02 + E20
Return probe anomaly
ERR 23
ERR 23
E23
Push button control panel anomaly
ERR 24
ERR 24
E24
Insufficient circulation
ERR 27
ERR 27
E27
Loss of remote control communication
ERR 31
ERR 31 / CM
E31 / CON
Low power supply voltage
ERR 37
not displayed
not displayed
Loss of flame signal
38
(only displayed on VIRGILIO palmtop, or within the "M1" / "P19" menu)
The VICTRIX ZEUS Superior kW I boiler signals any ano-
malies by the flashing symbol (5) along with the “ERRxx”
indication on the indicator (6) where “xx” corresponds to the
error code described in the following table. To eliminate the
block (where necessary), press the RESET "C" button positio-
ned on the boiler panel.