6
1
SI
NO
6
INS
TALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
AN
NO
YES
ATTENTION:
Installation of the Victrix Zeus 25 boiler
when powered by LPG must comply with
the rules regarding gases with a greater density
than air
(
remember, as an example, that it is
prohibited to install plants powered with the
above-mentioned gas in rooms where the
fl
oor
is at a lower quota than the country level
)
.
ATTENTION:
check the environmental operating
conditions of all parts relevant to in-
stallation, referring to the values shown in the
technical data table in this booklet.
ATTENTION:
it is not permitted to install boilers that
are removed and decommissioned from
other systems.
Th
e manufacturer declines all
liability for damages caused by boilers removed
from other systems or for any non-conformities
of such equipment.
Th
e Victrix Zeus 25 boiler has been designed for wall
mounted installation only; for heating and production
of domestic hot water for domestic use and similar
purposes.
Th
e place of installation of the appliance and relative
Immergas accessories must have suitable features
(technical and structural), such as to allow for (always in safe,
e
ffi
cient and comfortable conditions):
- installation (according to the provisions of technical legislation
and technical regulations);
- maintenance operations (including scheduled, periodic, rou-
tine and special maintenance);
- removal (to outdoors in the place for loading and transporting
the appliances and components) as well as the eventual replace-
ment of those with appliances and/or equivalent components.
Th
e wall surface must be smooth, without any protrusions or
recesses enabling access to the rear part.
Th
ey are not designed
to be installed on plinths or
fl
oors (Fig. 1).
By varying the type of installation the classification of the boiler
also varies, precisely:
-
Type B
23
or B
53
boiler if installed using the relevant terminal
for air intake directly from the room in which the boiler has
been installed.
-
Type C boiler
if installed using concentric pipes or other types
of pipes envisioned for the sealed chamber boiler for intake of
air and expulsion of
fl
ue gas.
Only professionally enabled companies are authorised to install
Immergas gas appliances.
Installation must be carried out according to regulation stand-
ards, current legislation and in compliance with local technical
regulations and the required technical procedures.
ATTENTION:
operators who install and service the
appliance must wear the personal pro-
tective equipment required by applica-
ble law.
1
BOILER INSTALLATION.
1.1 INSTALLATION RECOMMENDATIONS.
ATTENTION:
if installing a kit or servicing the ap-
pliance, always empty the system
’
s
domestic hot water circuit first so as not to
compromise the appliance
’
s electrical safety
(
see Par. 2.9 and 2.10
)
.