3.17 CASING REMOVAL.
To facilitate boiler maintenance the casing can
be completely removed by following these simple
instructions (Fig. 3-5):
- Remove the lower grid (1) by taking out the 4
fastening screws (2).
- Open the control panel door (3) remove the 2
white screw caps (4) and take out the 2 fasten-
ing screws (5), tilt the panel towards you.
- Unscrew the 2 (6) fastening screws of the casing
front (7) and release it by pushing it up.
- Loosen the screws (8) in the lower part of the
casing, loosen the 2 screws (9) of the 2 casing
sides (10) and unhook them from the slots (11)
present on the rear of the casing side.