3.20 TECHNICAL DATA.
Victrix Zeus Superior 26 2
ErP
Victrix Zeus Superior 32 2
ErP
Domestic hot water nominal heat input
kW (kcal/h)
26,9 (23137)
33.0 (28392)
Central heating nominal heat input
kW (kcal/h)
21,7 (18678)
33.0 (28392)
Minimum heat input
kW (kcal/h)
5,0 (4323)
7.3 (6279)
Domestic hot water nominal heat output (useful)
kW (kcal/h)
25,8 (22188)
32.0 (27520)
Central heating nominal heat output (useful)
kW (kcal/h)
21,0 (18060)
32.0 (27520)
Minimum heat output (useful)
kW (kcal/h)
4,7 (4042)
6.9 (5934)
*Effective thermal efficiency 80/60 Nom./Min.
%
96,7 / 93,5
96.9 / 94.5
*Effective thermal efficiency 50/30 Nom./Min.
%
104,3 / 106,0
104.7 / 105.8
*Effective thermal efficiency 40/30 Nom./Min.
%
106,5 / 106,5
107.3 / 107.3
Casing losses with burner On/Off (80-60°C)
%
0,70 / 1,00
0.87 / 0.20
Heat loss at flue with burner On/Off (80-60°C)
%
0,04 / 3,10
0.03 / 2.90
Central heating circuit max. operating pressure
bar
3
3
Maximum heating temperature
°C
90
90
Adjustable central heating temperature
°C
25 - 85
25 - 85
System expansion vessel total volume
l
7.1
7.1
Heating expansion vessel pre-charge
bar
1
1
Total volume domestic hot water expansion vessel
l
1.2
1.2
Domestic hot water expansion vessel pre-charge
bar
2.5
2.5
Appliance water content
l
6.7
9.1
Head available with 1000 l/h flow rate
kPa (m H
2
O)
26.0 (2.65)
29.0 (2.95)
Hot water production useful heat output
kW (kcal/h)
25.8 (22188)
32.0 (27520)
Domestic hot water adjustable temperature
°C
10 - 60
10 - 60
Domestic hot water circuit flow limiter at 2 bar
l/min
8.7
12.6
Domestic hot water circuit min. pressure (dynamic)
bar
0.3
0.3
Domestic hot water circuit max. operating pressure
bar
8
8
**Specific flow rate “D” according to EN 625
l/min
16.0
19.2
Flow rate capacity in continuous duty (∆T 30°C)
l/min
13.1
15.8
Domestic hot water performance classification according to N
13203-1
Weight of full boiler
kg
76.8
81.9
Weight of empty boiler
kg
70.1
72.8
Electrical connection
V/Hz
230/50
230/50
Nominal absorption
A
0.64
0.75
Installed electric power
W
85
105
Pump absorbed power
W
59
59
EEI
-
≤ 0,20 - Part. 3
≤ 0,20 - Part. 3
Fan power absorbed power
W
29
30.5
Equipment electrical system protection
-
IPX5D
IPX5D
Max temperature of combustion products
°C
75
75
NO
X
class
-
5
5
Weighted NO
X
mg/kWh
48
52
Weighted CO
mg/kWh
20
17
Type of appliance
C13 / C13x / C33 / C33x / C43 / C43x / C53 / C63 / C83 / C93 / C93x / B23p
/ B33 / B53p
Category
II2H3B/P
- Flue temperature values refer to an air inlet
temperature of 15°C and flow temperature of
50°C.
The data relevant to domestic hot water perfor-
mance refer to a dynamic inlet pressure of 2 bar
and an inlet temperature of 15°C; the values are
measured directly at the boiler outlet consider-
ing that to obtain the data declared mixing with
cold water is necessary.
- * Yields refer to the lower heating value.
- ** Specific flow rate ''D'': domestic hot water
flow rate corresponding to an average tem-
perature increase of 30K, which the boiler can
supply in two subsequent withdrawals.
Summary of Contents for VICTRIX ZEUS SUPERIOR
Page 1: ...VICTRIX ZEUS SUPERIOR 26 2 32 2 ERP Instruction and recommendation booklet IE 1 037935ENG...
Page 2: ......
Page 45: ...45...
Page 46: ...46...
Page 47: ...47...