39
3.22 TECHNICAL PARAMETERS FOR MIXED BOILERS (IN COMPLIANCE WITH REGULATION 813/2013).
The yields in the following tables refer to the higher heating value.
Model/s:
Victrix Zeus Superior 26 2 ErP
Condensing Boilers:
SI
Low temperature boiler:
NO
Boiler type B1:
NO
Co-generation appliance for central heating:
NO
Fitted with supplementary heating system:
NO
Mixed heating appliance:
SI
Element
Symbol
Value
Unit
Element
Symbol
Value
Unit
Nominal heat output
P
n
21
kW
Seasonal energy efficiency of central
heating
η
s
92
%
For central heating only and mixed boilers: useful heat output
For central heating only and mixed boilers: useful efficiency
At nominal heat output in high tempera-
ture mode (*)
P
4
21.0
kW
At nominal heat output in high tempera-
ture mode (*)
η
4
87.0
%
At 30% of nominal heat output in a low
temperature mode (**)
P
1
6.3
kW
At 30% of nominal heat output in a low
temperature mode (**)
η
1
97.2
%
Auxiliary electricity consumption
Other items
At full load
el
max
0.038
kW
Heat loss in standby
P
stby
0.104
kW
At partial load
el
min
0.014
kW
Ignition burner energy consumption
P
ign
0.000
kW
In standby mode
P
SB
0.005
kW
Emissions of nitrogen oxides
NO
X
43
mg /
kWh
For mixed central heating appliances
Stated load profile
XL
Domestic hot water production efficiency
η
WH
82
%
Daily electrical power consumption
Q
elec
0.193
kWh
Daily gas consumption
Q
fuel
23.816
kWh
Contact information
IMMERGAS S.p.A. VIA CISA LIGURE, 95 - 42041 BRESCELLO (RE) ITALY
(*) High temperature mode means 60°C on return and 80°C on flow.
(**) Low temperature mode for condensation Boilers means 30°C , for low temperature boilers 37°C and for other appliances 50°C of return tempera-
ture.
Model/s:
Victrix Zeus Superior 32 2 ErP
Condensing Boilers:
SI
Low temperature boiler:
NO
Boiler type B1:
NO
Co-generation appliance for central heating:
NO
Fitted with supplementary heating system:
NO
Mixed heating appliance:
SI
Element
Symbol
Value
Unit
Element
Symbol
Value
Unit
Nominal heat output
P
n
32
kW
Seasonal energy efficiency of central
heating
η
s
92
%
For central heating only and mixed boilers: useful heat output
For central heating only and mixed boilers: useful efficiency
At nominal heat output in high tempera-
ture mode (*)
P
4
32.0
kW
At nominal heat output in high tempera-
ture mode (*)
η
4
87.2
%
At 30% of nominal heat output in a low
temperature mode (**)
P
1
9.6
kW
At 30% of nominal heat output in a low
temperature mode (**)
η
1
96.7
%
Auxiliary electricity consumption
Other items
At full load
el
max
0.043
kW
Heat loss in standby
P
stby
0.145
kW
At partial load
el
min
0.016
kW
Ignition burner energy consumption
P
ign
0.000
kW
In standby mode
P
SB
0.005
kW
Emissions of nitrogen oxides
NO
X
47
mg /
kWh
For mixed central heating appliances
Stated load profile
XL
Domestic hot water production efficiency
η
WH
78
%
Daily electrical power consumption
Q
elec
0.386
kWh
Daily gas consumption
Q
fuel
24.802
kWh
Contact information
IMMERGAS S.p.A. VIA CISA LIGURE, 95 - 42041 BRESCELLO (RE) ITALY
(*) High temperature mode means 60°C on return and 80°C on flow.
(**) Low temperature mode for condensation Boilers means 30°C , for low temperature boilers 37°C and for other appliances 50°C of return tem-
perature.