© Adam Equipment Company 2004
12
•
When the current limits are shown, press [Func/C] to clear the
settings and then press the [Zero/Enter] key to store the zero
values.
6.7 ACCUMULATED TOTAL
•
The scale can be set to accumulate when a weight is added to
the scale automatically or manually by pressing [Print].
•
See Section 7 on PARAMETERS for details. The accumulation
function is only available when weighing. It is disabled during
percent weighing or parts counting.
•
The accumulated weights will be stored in the master unit of the
scale, i.e. kg or lbs.
•
If at any time the weighing units are changed, the accumulated
data will be lost.
6.8 MANUAL ACCUMULATION
•
When the scale is set to manual accumulation the weight
displayed will be stored in memory when the [Print] key is
pressed and the weight is stable.
•
The display will show "
" and then the total in memory for 2
seconds before returning to normal. If the optional RS-232
interface is installed the weight will be output to a printer or PC.
•
Remove the weight, allowing the scale to return to zero and put a
second weight on. Press [Print], the display will show "
"
and then show the new total.
•
Continue until all weights have been added.
•
To view the total in memory press the [Print] key when the scale
is at zero. The display will show the total number of items "
" and the total weight before returning to zero. The total will also
be printed via the RS-232 interface.
•
To erase the memory, press [Print] to view the totals and then
press the [Func/C] key to clear the memory.