5.4.1 Magnetic Calibration Procedure
Step 1:
Ensure that the ISD4000 has been physically installed in a location as free from
magnetic interference as possible (away from value packs, thrusters etc).
Step 2:
Check that the ISD4000 is mounted securely to the structure ensuring the unit is
not able to move independently from the structure.
Step 3:
If conducting the magnetic calibration in a workshop, ideally hang the ROV from
a crane away from magnetic sources. If conducting the calibration at sea, deploy the
ROV and move into open water, away from any structures with a magnetic property
(vessel, pipeline etc).
Do not conduct the calibration with the ROV on the vessel.
Step 4:
Run the seaView software, select the ISD4000 application and connect to the
ISD4000 unit:
seaView V3.0
seaView V1.9.0