5.0 Maintenance & Servicing
The ISS360 is a highly robust Sonar which has been designed to require minimal maintenance. Due
to this there are no user serviceable components.
Following use, the sonar should be rinsed in fresh water to remove particles and salt deposits. If
required a light detergent (such as that used to clean household dishes) can be used.
DO NOT USE SOLVENTS TO CLEAN THE UNIT
Following rinsing, the sonar should be dried with a cloth.
The connector should be cleaned and a light coating of Molykote 44 Medium grease should be
applied.
The sonar should be stored in its original case, in a cool, dry place.
It is recommended that the sonar be returned to Impact Subsea Ltd, on an annual basis to have a
‘health check’ and service conducted.