RS-1600-X24 User Guide
196
To configure the host channels:
1
From the System Menu, select
Configuration Menu
and press
Ente
r.
The Configuration Menu displays.
2
Select
Host Configuration
and press
Ente
r.
The Select Host Channel screen displays.
3
Select the host channel you want to configure and press
Ente
r.
The Topology screen displays. An * displays next to the current setting.
4
Select the option you want and press
Ente
r.
The Link Speed screen displays. An * displays next to the current setting.
5
Select the option you want and press
Ente
r.
The Target ID screen displays.
6
Select the option or number you want and press
Ente
r.
The CAPI LUN screen displays.
7
Select the option or number you want to use.
There is just one CAPI LUN for each SM module. The system confirms that you want to make the change.
8
Select
Yes
and press
Enter
to make the changes.
G.4 Understanding LUNs and Viewing
LUN Information
Each SM module supports up to 64 FC logical unit numbers (LUNs), or 128 after a failover, that are
numbered zero through 63. There are three different types of LUNs: CAPI, EMP, and partition. You can
view information about each LUN. See
G.4.1, ”Viewing LUN Information”, on page 197
.
The three types of LUNs have the following characteristics:
•
CAPI LUN
: Allows CAPI to configure the SM module. Each X24 can have a CAPI LUN. You only
need to assign a CAPI LUN if you are using CAPI to configure the X24 over a host channel using
SCSI protocol extensions. If you are not using CAPI, you can set the CAPI LUN to NONE. If you are
using CAPI, you can set it to a value of 0-63. For more information about changing the CAPI LUN,
see
G.3, ”Configuring the Host Channels”, on page 195
.
Note:
Most UNIX, Linux, and Macintosh operating systems require that the CAPI LUN be set to a
higher value than all array LUNs. Before creating your first array, change the CAPI LUN to a
higher value. If you are using a custom software application to configure and manage the
controller (this application uses CAPI to communicate with the controller), you must have a
CAPI LUN. If you are not using a custom application, and therefore are not using CAPI, select
NONE as the CAPI LUN. This allows your first array to be seen at LUN 0.
Summary of Contents for RS-1600-X24
Page 1: ...RS 1600 X24 User Guide Part No 43061 01A Issue 1 0 June 23 2003 ...
Page 9: ...Contents ix Index 229 ...
Page 10: ...x RS 1600 X24 User Guide ...
Page 50: ...RS 1600 X24 User Guide 32 ...
Page 56: ...RS 1600 X24 User Guide 38 ...
Page 70: ...RS 1600 X24 User Guide 52 ...
Page 112: ...RS 1600 X24 User Guide 94 ...
Page 170: ...RS 1600 X24 User Guide 152 ...
Page 190: ...RS 1600 X24 User Guide 172 ...
Page 206: ...RS 1600 X24 User Guide 188 ...
Page 230: ...RS 1600 X24 User Guide 212 ...
Page 238: ...RS 1600 X24 User Guide 220 ...
Page 246: ...RS 1600 X24 User Guide 228 ...