CAMERAS FRAME GRABBERS IMAGING SOLUTIONS
BOBCAT Hardware User’s Manual
IMPERX
Rev. 2.0.7
6421 Congress Ave.
4/8/2014
Boca Raton, FL 33487
www.imperx.com
+1 (561) 989-0006
248 of 329
10 – Dynamic DPC enable
11 – Static and Dynamic DPC enable
Data (31:2)
:
N/A
4.3.16.4
HPC Enable
This register enables the HPC (Hot Pixel Correction).
Address
:
0x0124
Data (1:0)
:
00 – HPC disable
01 – Static HPC enable
10 – Dynamic HPC enable
11 – Static and Dynamic HPC enable
Data (31:2)
:
N/A
4.3.16.5
FFC Enable
This register enables the FFC (Flat Field Correction).
Address
:
0x0128
Data (0)
:
0 – FFC disable
1 – FFC enable
Data (31:1)
:
N/A
4.4 DATA PROCESSING REGISTER DESCRIPTION
4.4.1 Image Enhancement Workspace Registers
4.4.1.1
Enhancement Mode Selector
This register selects the image enhancement mode of operation.
Address
:
0x0400
Data (3:0)
:
0x0 – enhancement disable
0x1 – single threshold binary
0x2 – dual threshold binary
0x3 – dual threshold with gray scale
0x4 – dual threshold with contrast enhancement
0x5 – single point correction
0x6 – multi point correction
Data (31:4)
:
N/A
4.4.1.2
Point X1 Position
This register selects the position value for point X1.