A.0 ABBREVIATIONS
RW
– read/write,
RO
– read only,
WO
– write only
MAX_HRZ_SZE, MIN_HRZ_SZE
– Max. and Min. horizontal image size – camera dependent
MAX_VER_SZE, MIN_VER_SZE
– Max. and Min. vertical image size – camera dependent
LIN_TIM_MIN
–
Minimum Line time – camera dependent
FRM_TIM_MIN
– Minimum Frame time – camera dependent
FRM_TIM_ACT
– Actual Current Frame time - variable
FRR_EXP_MIN
– Minimum Exposure time – camera dependent
A.1 SAVING AND RESTORING REGISTERS
Address
Register Name
Type
Usage
MIN Value
MAX Value
0x6000 Boot From
RW
00 - Factory,
01 - User 1,
10 - User 2
0x00000000
0x00000002
0x6060 Load From Factory
WO
Command
0x00000000
0x6064 Load From User1
WO
Command
0x00000000
0x6068 Load From User2
WO
Command
0x00000000
0x606C Load MFG Default Gain
WO
Command
0x00000000
0x6074 Save to User1
WO
Command
0x00000000
0x6078 Save to User2
WO
Command
0x00000000
0x0604
RS-232 Baud Rate
Selector
RW
<BAUD Value>
0x00000000 0x00000004
A.2 CAMERA INFORMATION REGISTERS
Address
Register Name
Type
Value
0x6004 Firmware Revision
RO
<Firmware Revision>
0x6008 Firmware Build Number
RO
<Firmware Build Number>
0x600C Test Register
RW
0x76543210
0x601C Soft Reset
WO
0xDEDBEEF
0x6080 Horizontal Frame Size
RO
<MAX_HRZ_SZE, MIN_HRZ_SZE>
0x6084 Vertical Frame Size
RO
<MAX_VER_SZE, MIN_VER_SZE>
0x6088 Current Minimum Frame Time
RO
<FRM_TIM_MIN>
0x608C Current Minimum Line Time
RO
<LIN_TIM_MIN> , <CLK_PER_PSC>
0x6090 Current Maximum Exposure
RO
<FRM_TIM_ACT>
0x6094 Current Minimum Exposure
RO
<FRR_EXP_MIN>
0x6098 Current Frame Number
RO
<Current Frame Number>
0x609C Current Camera Exposure
RO
<Current Exposure>
0x60A0 Current Frame Duration
RO
<FRM_TIM_ACT>
0x60B0 Current Image Size
RO
<CURT_VER_SZE>, <CRNT_HRZ_SZE>
0x60B4 Current AEC/AGC Status
RO
<Status Values>
0x6010 CCD Temperature
RO
<Current CCD Temperature>