CAMERAS FRAME GRABBERS IMAGING SOLUTIONS
BOBCAT Hardware User’s Manual
IMPERX
Rev. 2.0.7
6421 Congress Ave.
4/8/2014
Boca Raton, FL 33487
www.imperx.com
+1 (561) 989-0006
317 of 329
Figure E.3
CAUTION NOTE
It is strongly recommended that you DO NOT USE any other communication software to upgrade
the camera FW, RGS, DPC, HPC, FFC and LUT files.
If the user selects to upgrade camera firmware (.RPD file) and camera factory register space
(.RGS file), the camera firmware (.RPD) must be upgraded first.
During camera RGS or FW upgrade the camera power must be on all the time, and the process
must not be interrupted. If the camera is disconnected or the process canceled, this will result in a
user application firmware corruption. If such event occurs start the upload process again until
completion. If the upgrade process cannot be completed, the camera will power with the default
Factory Firmware so you can start the upgrade process again. If you need more information,
please contact IMPERX.