Remove the mounting plates from the feet, drill and 
fix them to the sub floor to secure them in position.

9

Using  a screwdriver and spirit level adjust the levelling
feet until all outside edges are level. 
Ensure the height is set correctly at this stage also.
(see diagram 5 on page 4 for further guidance)

10

At this stage we recommend that the waste pipe is buried
and the the starter section is bedded. This can be done by
pushing sand/cement under the section. It may be preferred
to temporarily remove the linear channel to do this.

11

Begin adding the first section, ensure it is fully located
and levelled correctly. (this illustration shows a corner 
section but this is dependant on the configuration type)

12

When making levelling adjustments it is important that
the feet are only just in contact with the sub floor, being 
careful not to over or under adjust.

8

Reposition the starter section and clip into the mounting
plates. Place the Linear channel into the starter section,
drill and fix in place. (also see drain assembly guide)

Ensure screw is fitted to

connect gully to Linear channel.

(do not over tighten)

Section 4: General Installation guidance 

for all configuration types

This section covers parts of the installation that are are common to all configuration types.

Please see section 5 and follow the relevant stages that are applicable to the type you are installing. 

Page 6

Summary of Contents for Aqua-Grade Linear

Page 1: ...assembly rules Section 4 General Installation guidance Section 5 Assembly methods If you require any further information about this product please contact our technical team on 01460 258 682 SAFETY Pl...

Page 2: ...ate SCR SPACER Spacer for moulded foot SCR FOOT Moulded foot SCR IMP Insulation mounting plate Optional available separately Can be used with both types of foot Section 1 Components Page 2 Parts used...

Page 3: ...gradient 2 Walls required 2 falls of gradient 3 Walls required 1 fall of gradient Section 2 Configuration types The Aqua grade Linear may be arranged in a wide range of sizes and configurations use th...

Page 4: ...lue corner section must always have 2 feet fitted When using configurations that start from a wall it is important that 2 feet are fitted to the first section to support the section properly excludes...

Page 5: ...clip the feet mounting plates onto levelling feet 4 Install the gully and waste pipe in an approved manner 6 Position the starter section correctly and mark the position of the mounting plates Tempora...

Page 6: ...ated and levelled correctly this illustration shows a corner section but this is dependant on the configuration type 12 When making levelling adjustments it is important that the feet are only just in...

Page 7: ...to prevent hollow areas 18 When fully filled it may be necessary to allow the screed to dry out slightly before final finish trowelling When complete the shuttering can be removed and the remaining fl...

Page 8: ...or 4 falls no walls configuration 5 Please follow these steps as a general guide for this type of configuration alternative sizes are available Always work in a clockwise or right to left direction Af...

Page 9: ...r 3 falls 1 wall configuration Please follow these steps as a general guide for this type of configuration alternative sizes are available Always work in a clockwise or right to left direction After e...

Page 10: ...lls corner drain can be assembled as Left hand and Right hand version The assembly process for these is slightly different please see notes below and assembly guide for these types on page 11 Parts fo...

Page 11: ...ls 2 walls configuration left and right hand Please follow these steps as a general guide for this type of configuration alternative sizes are available Always work in a clockwise or right to left dir...

Page 12: ...ly order for 1 fall 3 walls configuration Please follow these steps as a general guide for this type of configuration Always work in a clockwise or right to left direction After each row is completed...

Reviews: