background image

PAGE 17

c:

 Apply silicone sealant down the inside of the ‘long and short sides’ of the  

corner joints.

d:

 Push fit the corner joint caps on to the corner joints.

e:

 

Carefully

 push the ‘short side’ of the corner joints fully onto the main panel. 

A:

 

Aluminium threshold strip

 - Position the strip 

up against

 the corner joints.  

Run a bead of silicone sealant down the length of the threshold strips. Carefully push the 
return panels (the correct way around) into the corner joints (

1

). Slide the return panels 

down the corner joints and into the threshold strips (

2

). Wipe off any excess silicone.

B:

 

Plastic threshold strip

 - Position the strips onto the bottom of the return panels, 

flush with the edge (

1

). Carefully push the panels (the correct way around) into the 

corner joints (

2

) and ensure the strips make full contact with the floor. 

Options C & D -

 

continued

a

Option a:

 

Drilling floor for feet

 - Use the dimensions above to mark and drill the ‘pin’ holes in the 

floor. Using a 4mm drill bit, carefully drill shallow holes (no deeper than half the thickness of the tile 
etc.). Use the allen key to adjust the ‘pin’ in the inner feet

*

 to fit into the hole. Position the assembled 

feet in the marked position.

Option b:

 

Sealing feet to floor

 - Use the allen key to remove the ‘pins’ from the inner feet

*

. Apply 

silicone sealant to the underside of the inner feet. Position each assembled foot in the marked position.

b

17 

mm

17 

mm

mm

ø 4

mm

*

2mm

2mm

*

2

1

Inside 

11

Apply silicone sealant along the bottom of the panels and 

optional feet

, as shown. 

Without threshold strip

 - from outside only, seal along the bottom of the panels and the corner joints also 50mm up the joints between the corner joints and panels.

Aluminium threshold strip

 - from inside and outside, seal along the bottom and top of the threshold strips. From outside only, seal along the bottom of the corner joints. Also seal up the joints between the 

corner joints and threshold strips.

Plastic threshold strip

 - from outside only, seal along the bottom of the corner joints and up the joints between the corner joints and threshold strips.

Outside -  

Aluminium threshold strip

Outside -  

Plastic threshold strip

Outside -  

Without threshold strip

Outside of foot

Inside of foot

Options C & D -

 

continued

From inside, if required adjust the height of the feet (

1

) so that 

the return panels are vertical. 
Tighten the grub screw (

2

) onto the return panels.

 

Push fit the screw cover caps.

3mm

MAIN 

PANEL 

(outside)

c

d

e

2

1

A

B

1

2

Sealant

A

Summary of Contents for AQUA SCREEN PURE

Page 1: ...uture reference Incorrect fitting will invalidate the guarantee SAFETY Handle glass with care Although the glass is very tough sharp impacts can damage both the glass and metal frame Do not remove the...

Page 2: ...outside of the panel Satin glass patterns MUST be installed to the outside of the panel Note The Glass Guard coating is on the opposite side to the label or satin glass patterns 5 4 If using the thre...

Page 3: ...6 Remove the panel from the wall channel Carefully trim your chosen threshold strip down to the same width as the panel Measure the height of the threshold strip X and remove the same amount off each...

Page 4: ...ie bar g From inside tighten the grub screw 1 onto the panel Ensure the panel is vertical and tighten the grub screw in the top of the bracket onto the tie bar 2 Push fit the screw cover cap 10 Push f...

Page 5: ...he correct way around into the wall channel Note Wetting the edge of the panel with water will help the panel insert If not using the threshold strips proceed straight to step 7 4 If using the thresho...

Page 6: ...position of the angled tie bar bracket onto the wall Approx 250mm PN80499 PN80499 3mm 2mm 2mm 6 Remove the panel from the wall channel Carefully trim your chosen threshold strip down to the same widt...

Page 7: ...he grub screw 1 onto the panel Ensure the panel is vertical and tighten the grub screw in the top of the bracket onto the tie bar 2 Push fit the screw cover cap 10 Tighten the large screws on both of...

Page 8: ...PN10754 Wall channel PN10754 1 Plan position of panels The size of the opening will depend on the tray if used or the site conditions To fit the DOUBLE PANEL WITH ANGLED TIE BARS option follow the sam...

Page 9: ...ss Guard coating is on the opposite side to the label or satin glass patterns Tie bar PN10786 Wall channel PN10754 Corner joint PN11011 5 4 If using the threshold strip s there are 2 types available A...

Page 10: ...r joint short side as shown onto the main panel b Carefully measure and trim your chosen threshold strip down to the width of the panel minus the corner joint c Measure the height of the threshold str...

Page 11: ...Ensure the panel is vertical and tighten the grub screw in the top of the bracket onto the tie bar 2 Push fit the screw cover cap 10 Push fit the top cap onto the top of the wall channel 32 mm a 1 2...

Page 12: ...oot so it is flush with the underside Place the inner foot into the foot Position the assembled foot under the return panel flush with the edge d Ensure the return panel is vertical and if required ad...

Page 13: ...ling foot to floor Use the allen key to remove the pin from the inner foot Apply silicone sealant to the underside of the inner foot Position the assembled foot in the marked position b 15 Apply silic...

Page 14: ...e wall b If required trim the tie bars to length X 50mm c Assemble the tie bars slide on the top panel brackets and tie bar brackets Lightly tighten the fitted grub screws X Wall Opening X 50mm a b c...

Page 15: ...e tie bars 2 Push fit the screw cover caps 32 mm a c d b 2mm 1 2 g Inside 3mm 5 a Carefully place the tie bar assemblies onto the glass approximately 100mm from the edges depending on your installatio...

Page 16: ...el c Use the 3mm allen key to wind up the pin on each inner foot so they are flush with the underside Place the inner feet into the feet Position the assembled feet under the return panels flush with...

Page 17: ...hole Position the assembled feet in the marked position Option b Sealing feet to floor Use the allen key to remove the pins from the inner feet Apply silicone sealant to the underside of the inner fee...

Page 18: ...nel with water will help the panel insert 6 mm a b d 32 mm 1180mm max c PN80499 PN80499 PN80506 5 4 Ensure that the open end of the panel is vertical and the panel is parallel with the opposite wall W...

Page 19: ...ten the large screws on both tie bar brackets 7 Push fit the top cap onto the top of the wall channel 32 mm a 1 2 c d g Inside b 3mm 2mm 8 Foot Options Option A Without foot follow step 10 Option B Wi...

Page 20: ...contains materials such as aluminium and glass which can be recycled Please contact your local authority to find your nearest recycling centre TECHNICAL HELPLINE 01460 258682 PAGE 20 10 Seal along th...