background image

Suggested pipe

 exit points

 15 

 28 

 40 

Radiate Shower Tray

Installation Guide

The tray design allows for 15mm pipe-work to be concealed around the underside perimeter of the tray. See 

suggested pipe-work routes and exit points. When the desired exit point has been established the side of the 

shower tray will need to be carefully drilled with a 16mm hole saw or similar.

Due to limited clearance space under the shower tray push-fit fittings must not be used.

Do not use elbow fittings, pipe-work should be bent using a pipe bender to reduce the risk of blockages.

We recommend installing with Impey half-height shower doors and ramp kit for easy access.

Fig 1.

Page 6

1:1 SCALE

Cut out and use as template if desired

Summary of Contents for Radiate Shower Tray

Page 1: ...alidate the guarantee Make sure there are no hidden pipes or cables in the floor or walls where you intend to drill Wear safety goggles shoes and appropriate clothing CARE Please protect during the sh...

Page 2: ...tion Guide Component Content List Radiate Shower Tray Suggested Equipment needed Spirit level pencil silicone sealant tape measure knife 15mm copper tube pipe bender ABS solvent cement trowel power dr...

Page 3: ...o the tray using the screw provided Ensure the seal is positioned correctly and do not over tighten the screw Ensure the waste is assembled correctly incorrect alignment or assembly may result in a le...

Page 4: ...Guide Correct Waste Assembly Page 3 The waste outlet must be aligned as shown in this illustration If the waste is assembled as shown here it will not tighten correctly and result in a leak Under norm...

Page 5: ...stallation Guide Correct Correct Incorrect Page 4 The waste outlet must be aligned as shown in these 2 illustrations Any direction other than shown here is incorrect and may result in a leak This illu...

Page 6: ...xposing to water The tiling can now be completed Radiate Shower Tray Installation Guide Fit the pump and connect up to the tray pipe work Ensure that the pipe work is not under strain when connected W...

Page 7: ...been established the side of the shower tray will need to be carefully drilled with a 16mm hole saw or similar Due to limited clearance space under the shower tray push fit fittings must not be used...

Page 8: ...iness Park Ilton Somerset TA19 9EA TEL 01460 256090 FAX 01460 259800 info impeyshowers com www impeyshowers com If you require any further information about this product please contact our technical d...

Reviews: