13
IST STP101.147 GB-23-12-20
EN
7 - Maintenance
ATTENTION : All maintenance operations must be carried out exclusively
by qualified and informed personnel.
WARNING : before proceeding with any ordinary and extraordinary
maintenance operation, check that the appliance is not electrically
powered.
Check the proper functioning of the appliance yearly, so that it is possible to carry out any needed
maintenance and/or repair in due time. In particular, it is recommended to check:
- current absorption and safety devices of the appliance;
- the good conditions of the hanging systems;
- the good connection of the lamps and their condition (useful lifetime max. 9.000 hours)
- the cleanliness of the appliance and, in particular, the cleanliness of the protection shielding.
Use adequate cleaning products that do not affect or compromise the materials of the appliance and
the electrical cables.
In order to perform the maintenance properly, remove the upper cover by unscrewing its screws, as
illustrated in the following pictures.
Once the upper cover is removed, all the internal components become accessible (see pictures
below).
Unscrew the fixing
screws on the upper
Remove the upper cover
Press the red button to remove lamp from the
lampholder
Remove the fuse holder to access the fuse
(fuse 5x20 2A)