MODEL NUMBER:
HMW700-0-0-NN-XX HMW701-0-0-NN-XX
Wiegand Reader
Module
Impro (WRM) Wiegand Reader Module
INSTALLATION MANUAL
SPECIFICATIONS
The WRM is a Cluster Expansion Module that works in conjunction with an Impro
(CCM) Cluster Controller Module; offering a Wiegand Reader Interface solution that is
adaptable and scalable, while also accommodating legacy hardware and software
suites.
Working Environment
Plastic Housing
............................
(HMW700)
Designed to work in an indoor (dry)
environment similar to IP20. The Module is
not sealed against water.
PCB Card for IPS / 19” Rack
.......
(HMW701)
Designed to work in an indoor (dry)
environment similar to IP20. The Card is not
sealed against water.
Power
Input Voltage
................................
12 V DC to 15 V DC, polarity protected.
Power Requirements
Current (mA)
Power (W)
12 V DC with no Readers
connected and relays off ........ 37
0.44
12 V DC with both relays
activated and maximum
reader load ............................. 503
6