background image

Mounting the Impro (WRM) Wiegand Reader Module 

CAUTION:  Make certain that you mount the WRM on a vibration-free surface. 

NOTE:    The WRM can be mounted onto virtually any surface including metal. 
NOTE:    Cluster Modules are Hot-Swappable – it is not necessary to power them 

down when adding, removing or wiring them up. 

 

Clustering 

Provided there are less than eight other Expansion Modules already clustered with the 

Cluster Controller, you may add the WRM to an existing Cluster: 

 

 

  Remove the Housing Cover from the WRM and plug the WRM into the Cluster 

Socket on the right hand side of the Cluster Controller – or that of the 

outermost Expansion Module in the cluster. 

  Holding the WRM square against its neighbouring Module, mark the mounting 

hole locations through the mounting holes in the back of the Housing Base. 

  Remove the WRM, drill the mounting holes. 

  Use the plastic Stand-Offs to provide space for cables behind the cluster, or if 

the other modules in the Cluster are already mounted with stand-offs. 

  Mount the WRM Housing Base firmly to the mounting surface using fasteners 

(not included) appropriate for the mounting surface material. 

  Select the gland plates that best suit the installation and/or knock out the 

cable entry points as needed. 

  Connect the reader cables, the digital inputs and the relay terminals as 

necessary for the installation 

  Commission the WRM (and its readers) via the menu options on the Access 

Control Application.  

  Replace the WRM Housing Cover and fasten closed with the two Allen head 

screws provided. 

 

 

 

 

 

 

Blank Space 

 

 

 

 

HMW300-0-0-GB-00 

October 2013 

Page 7 

 

Summary of Contents for HMW700-0-0-NN-XX

Page 1: ...odating legacy hardware and software suites Working Environment Plastic Housing HMW700 Designed to work in an indoor dry environment similar to IP20 The Module is not sealed against water PCB Card for...

Page 2: ...S Bus See WRM Address Information on page 17 for Address usage with one Reader connected Reader Options Reader 1 Wiegand and Reader 2 Wiegand allow connection to the following hardware Impro MDR Mult...

Page 3: ...ly Open state By placing Resistors into the circuit between either Reader 1 Inputs DOS 1 or Reader 2 Inputs DOS 1 and GROUND GND the Module s Digital Input monitors a constant resistance through the c...

Page 4: ...hrough the cover of the housing Five Ziploc bags containing the following Four Stand Offs for spacing the WRM away from the mounting surface and two Cluster Connector Covers for closing off the cluste...

Page 5: ...when it would be convenient to install a WRM some distance from its Cluster Controller The following applies The maximum S Bus Cable length from the Cluster Controller to the WRM is 150 m 490 ft A max...

Page 6: ...de Remote The maximum cable distance between the Impro WRM and its Multi mode Remote MUST NOT exceed 10 m 33 ft Achieve this by using good quality screened twisted pair cable Distance between Reader U...

Page 7: ...st its neighbouring Module mark the mounting hole locations through the mounting holes in the back of the Housing Base Remove the WRM drill the mounting holes Use the plastic Stand Offs to provide spa...

Page 8: ...ng surface using fasteners not included appropriate for the mounting surface material Select the gland plates that best suit the installation and or knock out the cable entry points as needed Connect...

Page 9: ...PIN code or Reason Code Mode Sagem MA100 MA200 MA300 or Sagem J Series 8 Wiegand open format 9 LEGACY UHF Receiver Support If the UHF Receiver is connected then Button 1 of the Quad Transmitter repor...

Page 10: ...de in Tag PIN Reason Mode If the Impro WRM expects a PIN code and receives a number greater than 65535 then the WRM assumes the number to be a tag code The WRM discards the previously read Tag for the...

Page 11: ...ELECTRICAL CONNECTIONS Key Component Positions Figure 3 Impro WRM Key Component Positions HMW300 0 0 GB 00 October 2013 Page 11...

Page 12: ...Figure 2 for Arc Suppression details NOTE The ideal cable distance between the Impro WRM and its Multi discipline Reader MUST NOT exceed 150 m 164 yd NOTE This diagram shows typical connections to th...

Page 13: ...Reader WKM900 or the Wiegand Junction Box Reader WJB900 use the cable colours displayed in brackets NOTE Connection details remain the same for all Wiegand models NOTE Use the connections shown here...

Page 14: ...WRM Connected to a Multi mode Remote NOTE Connection details remain the same for all Multi mode Remote models NOTE The cable distance between the Impro WRM and its Multi mode Remote MUST NOT exceed 1...

Page 15: ...Connecting other Devices Figure 7 Connecting other Devices to the WRM HMW300 0 0 GB 00 October 2013 Page 15...

Page 16: ...mpro WRM and its relay driven loads in an unclustered remote installation position Figure 8 Typical S Bus and Power Wiring for Remote Installation NOTE The wiring of the RTE DOS and Reader Terminals r...

Page 17: ...witches off and no MDR is connected to one channel the fixed address for the un used channel will be hidden In all other instances both addresses on the WRM are always shown Fixed Address Label Once t...

Page 18: ...USER NOTES HMW300 0 0 GB 00 October 2013 Page 18...

Page 19: ...USER NOTES HMW300 0 0 GB 00 October 2013 Page 19...

Page 20: ...and HMW701 0 0 GB 00 The last two digits of the Impro stock code indicate the issue status of the product HMW300 0 0 GB 00 Issue 01 October 2013 Impro Access Portal WRM Wiegand Reader Module English...

Reviews: