SPECIFICATIONS
Working Environment
.................
The ImproX RH is designed to work in an
indoor (dry) environment similar to IP20. The
ImproX RH is, therefore, NOT sealed against
water.
Scanner Operation
.......................
125 kHz and 13.56 MHz (ImproX Mifare
Remotes).
Input Voltage
................................
10 V DC to 30 V DC.
Power Requirements
Current (mA)
Power (W)
Input Voltage 10 V DC ...........
100
1.0
Third-party Port
...........................
5 V DC
0.1 V is supplied to power the single
Reader connected to this Port. A maximum of
100 mA can be supplied from this Port.
Installer Interfaces
LED Indicators
Power LED .....................
Blue (steady) (externally visible).
USB Tx LED ...................
Red (flashing) (internally visible).
USB Rx LED ...................
Green (flashing) (internally visible).
RS485 Tx LED ................
Red (flashing) (internally visible).
RS485 Rx LED ...............
Green (flashing) (internally visible).
ImproX RRA or RRM
Status Indicator
Status LED ..............
Bi-colour, Red or Green LED.
Buzzer
Volume and Tone ......
Four volume, single tone (Software
dependent).