22
IMS PULSEMIG 270
EN
WELDING STAGES
Standard 2 times mode
O
FF
Is
ta
rt
Dstart
Ga
s
Pr
e-
Fl
ow
T burn-back
I b
ur
n-
ba
ck
O
N
Gas post-Flow
Pressing the trigger will start pre-gas. When the wire touches the workpiece a pulse boots the arc and the the
welding process starts. When you stop pressing the trigger, the wire feeder stops working and a current pulse will
cut the wire, and will be followed by post-gas. As long as the post gas is not finished, you can pull the trigger to
carry on the welding (delay in manual). To modify the parameters you have to wait until the end of the post gas.
Standard 4 times mode
O
N
Is
ta
rt
Dstart
G
as
P
re
-F
lo
w
T burn-back
I b
ur
n-
ba
ck
O
N
Gas post-Flow
O
FF
O
FF
In standard 4T, the time of the pre-gas and post-gas is managed by the trigger.
2 times pulse process
O
FF
Is
ta
rt
Dstart
I h
ot
s
ta
rt
T hotstart
T upslope
G
as
P
re
-F
lo
w
V
ite
ss
e
d'
ap
pr
oc
he
T downslope
I blackout
T burn-back
I b
ur
n-
ba
ck
O
N
Gas post-Flow
I
Soft-start
Summary of Contents for PULSEMIG 270
Page 1: ...73502_V3_01 11 2015 FR EN DE 3 13 38 44 14 24 38 44 25 37 38 44 IMS PULSEMIG 270 ...
Page 43: ...43 ...
Page 44: ...44 ...