80
IMT 2003i Technical Specifications & Parts Manual # 99904385
Turntable Bearing Tilt Test
1
Place crane in vertical position.
2
Set a dial indicator at 0 on the pinion cover plate at back side of mast.
3
Lower crane to the horizontal position.
4
Check and record the dial indicator change. It should not exceed the tilt measurement noted
in the chart below.
5
Return the crane to the vertical position. The dial indicator should return to 0.
Set up dial indicator
to 0" on pinion cover
at back side of mast.
Lower crane to
horizontal position.
Read dial indicator.