Compressor Installation Notes
Satisfactory installation depends upon the ability of the installer. Refer to the installation drawing
below for the foundation plan for the IMT CAS2545 air compressor installation. When installing,
choose a location that will permit top access to service the unit. The required clearance is 28-
inches. Compressor performance is optimum with a level installation. The maximum tilt allowed
is 20°. You do not need to use isolators with installation - the gasket material is sufficient.
Use hydraulic connections and hoses of proper size. Smaller hoses and fittings will reduce
compressor performance. IMT recommends the following:
•
Pressure Hose: 12 (3/4") rated at 3125 PSI (100R2)
•
Return Hose: 12 (3/4") rated at 300 PSI (100R4)
•
Air Discharge Hose: 3/4" air hose rated at 250 psi and 185° F