22
IMT CAS3560 Air Compressor Manual Part No. 99903566
Compressor Installation (99903532)
Satisfactory installation depends upon the ability of the installer. Refer to the installation drawing
below for the foundation plan for the IMT CAS3560 air compressor installation. When installing,
choose a location that will permit top access to service the unit. 28-inches of clearance are
required. Compressor performance is optimum with a level installation. The maximum tilt
allowed is 20°. You do not need to use isolators with installation - the gasket material is
sufficient.
ITEM #
PART #
DESCRIPTION
QUANTITY
1.
76396381
GASKET, COMPRESSOR MT.
2
2.
72062821
WASHER, 3/8 BONDED PLT
6
3.
72063051
WASHER 3/8 LOCK
6
4.
72060047
CAP SCR 3/8-16X1.25 GR5Z (WAS 72060046)
6
Use hydraulic connections and hoses of proper size. Smaller hoses and fittings will reduce
compressor performance. IMT recommends the following:
•
Pressure Hose: 12 (3/4") rated at 3125 PSI (100R2)
•
Return Hose: 12 (3/4") rated at 300 PSI (100R4)
•
Case Drain Hose: 6 (3/8") rated at 2250 PSI (100R1)
•
Air Discharge Hose: 3/4" air hose rated at 250 psi and 185° F