20
CAS440HT Air Compressor Manual Part # 99900838
1000 RPM MAXIMUM! Operating this unit in excess of 1000 RPM, measured at the
compressor flywheel, will void your warranty. Engine RPM may be different.
5
The flow required to the compressor is 16 GPM.
Shutdown
Shut down the compressor system as follows:
1
Allow the compressor to build to maximum pressure and the truck engine will automatically
idle down.
2
Place the compressor control valve in the open (off) position.
3
Depress the clutch pedal and disengage the PTO.
4
Open the receiver drain cock and discharge the air in the receiver.
WARNING
Federal law prohibits driving the carrier vehicle on public roads with the receiver filled with
compressed air. Always drain the receiver before moving the vehicle.