SD Logger
4
instruction manual[X519009-3]
24/28
<2020/03/03>
(
3
rd
edition
)
Ⅷ
Enhanced function
・
Difference from logger 3
SD logger 4 has the following enhanced functions compared to conventional SD
logger 3.
1.
A fast bit rate has been added.
A bit rate of 115200 (bps) has been added.
2.
Status file
When the power is turned on, the status of the logger is written to the following
status file.
It is possible to check the setting status and operation status by importing the
status file to a personal computer and viewing it with an editor.
●Status file
File name
STATUS.TXT
Folder
Root folder
●Status file format
Item
Example
Name / Version
DT-MC04 V400
Start-up time
2018/02/15 12:57:34
Model
script
Communication
setting
9,600bps 8bits 1stop parity:non
Flow control
rts-control:disable
Communication error
automatic clear
comm-error:auto-clear
The status file is rewritten every time the power is turned on, and the status at
the time of the last startup can be checked.
However, if the status file is set to the write-protected attribute, it cannot be
rewritten.
Even if an error occurs when writing the status file, the LED does not blink or the
buzzer does not sound, and the subsequent operations continue as they are.