12

13

IV. InBody Test

Weight Measurement and InBody Test: Step on the footplate 

  barefoot and stand as shown in the  fi gure below.

  Hold the hand electrodes as previously described. After fi nishing the weight    
  measurement, a "beep-beep" will sound and the InBody Test begins. The Test runs  
  for about 10 seconds and is fi nished when a “tu-lu-lu“ sounds. Once “End” appears  
  on the screen, step down from the footplate.

If a user’s  palms and/or soles  are dry or callused, he or she may have diffi  culty 

testing. Wipe hands and feet with an InBody Tissue for more accurate results.

Summary of Contents for H20N

Page 1: ...User s Manual Disclaimer This device is not a medical device It cannot determine the presence of an illness or disease The examination of a medical professional is required for diagnosis ...

Page 2: ...dy Test Posture Stretch out your arms Avoid contact with your waist Put your thumb on the round electrodes Place your heel at the end of the heel electrodes and allow the rest of your foot to point forward ...

Page 3: ... C Interlocking BodyKey App with InBody H20N Weight Measurement InBody Test A Precautionary Steps B Test Posture C Test Instructions D Understanding InBody Outputs Troubleshooting A Error Message B Solving Simple Problems Frequently Asked Questions FAQ Specifications Product Warranty I II III IV V VI VII 2 3 4 6 8 9 10 11 15 16 17 18 20 ...

Page 4: ...essively high or low temperatures humidity and pressure can affect the accuracy of the InBody 6 Keep food beverages and other liquids away from your InBody device 7 Do not disassemble the InBody It can cause electric shock or damage product malfunction and other errors InBody Co Ltd will not be liable for any incidental or consequential injuries or damages from the product that occurred 8 Do not u...

Page 5: ...er holds the device with hands and fingers Foot electrodes User stands on the device placing the back of heels on the rear electrodes Footplate Measures the weight of the user Battery insert The InBody H20N takes 4AAbatteries Open the cover to insert the batteries Back cover Do not open dismantle or attempt to repair your device yourself Display screen Dial Foot electrodes Footplate Hand electrode...

Page 6: ...lation and User Registration of BodyKey app Download and install the BodyKey App from the iPhone App Store or Google Play Store prior to testing iOS 8 or newer Android 5 0 or newer Or Once the download is complete open the BodyKey app ...

Page 7: ...5 II Product Components Keep the Bluetooth ON to use the InBody H20N ...

Page 8: ...6 II Product Components C Interlocking the InBody App with BodyKey H20N ...

Page 9: ...7 II Product Components Data will transmit from the BodyKey App automatically after syncing is complete ...

Page 10: ...ement is complete The power turns off automatically when you step off the footplate Zero Point Adjustment When the device is being calibrated a scrolling rectangle will appear on the screen If you want to test on the InBody H20N immediately after measuring weight turn the dial and input height Then hold the hand electrodes and stand with the correct test posture to take the InBody Test ...

Page 11: ...s Do not eat immediately before testing on the InBody Test in the morning if possible Test after going to the bathroom Test prior to working out Test prior to taking a shower bath or using a sauna Stand for about 5 minutes prior to testing ...

Page 12: ... are not stuck between foot electrodes and your feet Arms are extended Arms are bent Hold the hand electrodes and extend your arms Arms are too high Arms are too low Do not let your arms touch your stomach and make sure your arms are extended from your body and wear light clothes with sleeves Arms and legs aren t touching each other Put your thumbs on the round electrodes and hold them Do not let ...

Page 13: ...Instructions Power ON Press the dial to turn the power on Enter height Press the dial to enter height When the power is on the height of the previous user is displayed Be sure not to press the footplate while adjusting the dial ...

Page 14: ...12 IV InBody Test Run BodyKey App After running the app go to InBody Test page and press Connect button to start InBody Test Step on the InBody H20N to begin testing ...

Page 15: ...ter finishing the weight measurement a beep beep will sound and the InBody Test begins The Test runs for about 10 seconds and is finished when a tu lu lu sounds Once End appears on the screen step down from the footplate If a user s palms and or soles are dry or callused he or she may have difficulty testing Wipe hands and feet with an InBody Tissue for more accurate results ...

Page 16: ...isplayed for 100 seconds after an InBody Test has completed If the device is not used within that timeframe it will turn off To turn off the device immediately after use press and hold the dial When synced with the App Data will automatically sync between the InBody H20N and BodyKey App IV InBody Test ...

Page 17: ...m for diagnosing obesity The standard range is 10 20 for men and 18 28 for women The standard body fat percentage differs for children under 18 depending on their gender and height Muscle Mass Skeletal Muscle Mass Skeletal muscle represents the majority of muscle tissue and powers movement of the skeleton Skeletal muscle is innervated by the somatic nervous system and is subject to voluntary contr...

Page 18: ...ion occurs Error messages caused by incorrect testing posture If the following error messages appear do not put your socks or stockings on Check your testing posture and try again Error messages caused by internal malfunction of the InBody H20N If the following error messages appear please contact InBody ...

Page 19: ...ht is not measured and the screen displays a scrolling rectangle A1 Tap the footplate to turn on the device Once 0 0 appears on the LCD screen step on the footplate and measure weight A2 This can happen when the batteries are not inserted correctly Remove the batteries and make sure the electrodes are in the correct spots Q3 Weight is inaccurate A1 Tap the footplate to turn on the device Once 0 0 ...

Page 20: ... hands and or feet clean them with an InBody Tissue before testing InBody recommends testing during the same time of day under the same conditions for accuracy Q2 What is the normal range of visceral fat level A Visceral fat level is InBody s method of level display which leveled cross section of visceral fat from 1 to 20 For adults it is normal if visceral fat level is below 10 The lower the visc...

Page 21: ...ults Q5 If the user s thighs or armpits touch would that affect the test results A Yes If the user s thighs or armpits touch have him or her wear a light short sleeve shirt and shorts to obtain more accurate results Q6 How do you make the results stay on the screen longer A InBody Test results are shown on the LCD screen for 100 seconds If you want to see it for a longer period of time turn the di...

Page 22: ...edance Analysis Method DSM BIA type Body Composition Calculation Method No Empirical Estimation Outputs LCD Screen Weight Percent Body Fat Muscle Mass Visceral Fat Level Applied Rating Current 100 Power Consumption DC 6V 1 5V AA battery 4 EA Display Type Customized LCD Dimension 310 3 W 356 4 L 58 3 H mm Weight 2 7 kg Testing Time Within 8 seconds after measuring impedance Operation Environment 10...

Page 23: ...s equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different fr...

Page 24: ...f charge during the warranty period 4 The warranty will be voided and repair services will be offered at cost under the following circumstances Failure and or damage caused by mishandling Failure and or damage caused by not following the directions and precautions stated in the User s Manual Failure and or damage caused by a natural disaster Failure and or damage caused by a power malfunction 5 Th...

Page 25: ... prior written consent from InBody Co Ltd under the copyright laws This manual might have typographical errors and its content can be changed without prior notice InBody Co Ltd shall not be liable for any errors incidental or consequential damages that occurred by not complying with the contents of the Users Manual ...

Page 26: ......

Page 27: ......

Page 28: ... E mail inbody inbody co jp InBody China CHINA Biospace China Co Ltd 903 904 XingDiPlaza No 1698 YiShanRoad Shanghai 201103 China TEL 86 21 64439705 FAX 86 21 64439706 Website inbodychina com E mail info inbodychina com InBody India INDIA InBody India Pvt Ltd Unit No G B 10 Ground Floor Art Guild House Phoenix Market City L B S Marg Kurla West Mumbai 400070 India TEL 91 22 6223 1911 Website inbody...