22
GB
Table 1 Liquid Gas Natural Gas
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
20
17
25
28-30
20
35
37
25
45
Fast (R)
Reduced Fast (RR)
Ultra Rapid (UR)
Semi Fast (S)
Auxiliary (A)
Mini WOK (MW)
Supply pressures
Burner
Diameter
(mm)
Thermal Power
kW (p.c.s.*)
100
100
100
75
55
110
3.00
2.60
3.40
1.65
1.00
3.50
Nomin. Reduc.
0.70
0.70
0.70
0.40
0.40
1.30
By-pass
1/100
(mm)
39
39
39
28
28
61
Nozzle
1/100
Flow*
g/h
(mm)
***
86
80
91
64
50
91
Nozzle
1/100
Flow*
l/h
(mm)
116
110
123
96
79
138
286
248
324
157
95
333
218
189
247
120
73
254
**
214
186
243
118
71
250
Burner and nozzle specifications
*
At 15°C and 1013,25 mbar - dry gas
**
Propane
P.C.S. = 50.37 MJ/Kg
***
Butane
P.C.S. = 49.47 MJ/Kg
Natural
P.C.S. = 37.78 MJ/m
3
A
S
R
S
A
UR
RR
S
S
A
MW
RR
S
S
IP 750 S
IP 751 S
IP 751 S R
IP 640 S
IP 640 S R