1.3 DESCRIPTION OF THE PNEUMATIC CIRCUIT:
The pump is connected to the vacuum station (under the glass shelf) by a 7 mm
diameter silicone rubber hose lodged in the cabinet by embedding in foam and
coupled to the shelf at the rear of the fridge wall
The vacuum pump compartment also contains:
1 The vacuum switch responsible for detecting
vacuum conditions inside the container and con-
sequently disconnecting the vacuum pump.
2 A filter coupled to the aspirated air extraction
hose.