O
PERA
T
I
ON
G
B
11
Service Manual
Ne
w
E
lectronic Cold Platform 2005
Edition
2005.03.25
Language
E
nglish
T
E
MP
E
RATUR
E
S
E
TTING:
Turn the refrigerator knob (2) or freezer knob (6)
clockwise to decrease the temperature or
counterclockwise to increase the temperature until
reaching the minimum position; when the refrigera-
tor knob is set to minimum the refrigerator compart-
ment will be switched off, while setting the freezer
knob to minimum switches off the entire appliance.
“SUP
E
R COOL” FUNCTION:
T
E
MP
E
RATUR
E
DISPLAYS (7–S
E
GM
E
NT):
The displays serve to show the user temperature
setting for the refrigerator compartment and the
freezer compartment in accordance with the posi-
tion of the knob. Freezer compartment temperature
is from -18°C to -26°C, while refrigerator compart-
ment temperature is from +3°C to +8°C.
I
f either the
refrigerator or freezer is switched off, the display (7–
segment) will remain blank.
This function allows optimal chilling of large quanti-
ties of food in the refrigerator compartment by alter-
ing the refrigerator On and Off set-points in accord-
ance with parameters stored in the EEPROM
memory.
Activating this function forces the fridge fan, which
starts after a time parameterised in the EEPROM
memory, to run continuously to obtain the maximum
cooling capacity in the refrigerator compartment. The
SUPER COOL function cannot be activated if either
of the two freezer temperature alarm conditions is
active. Activation of an alarm mode or switching off
the appliance or only the refrigerator compartment
automatically causes this function to be deactivated.
Press button (1) to activate the function.
I
n the case
of the basic interface LED (3) will illuminate confirm-
ing activation of the function. Deactivation of the
SUPER COOL function can be performed by the
user pressing the relative button again, or will occur
automatically at the end of the procedure (number
of cycles) as defined in the EEPROM memory.
I
f the appliance is equipped with the Digit interface,
the relative 7-segment display will show tempera-
ture 1 until deactivation of the function, at which point
the display will return to the temperature value set
on the freezer knob. The user can also activate the
ECO or HOL
I
DAY functions, which will become op-
erational as soon as the SUPER COOL function has
been deactivated The SUPER COOL function can-
not be selected if the HOL
I
DAY function is active.
I
n
case of electrical power failures the function is re-
sumed automatically when power is restored, com-
pleting the remaining cycles except in the presence
of a temperature alarm
Summary of Contents for New electronic cold platform 2005
Page 73: ......