E
R FUNCTION:
This function provides optimal freezing of food in the
freezer compartment, conserving properties of tex-
ture and flavour.
Activating this function forces the compressor run
continuously thereby obtaining maximum freezing
power in the freezer compartment.
The fan starts after a time interval parameterised in
the EEPROM memory from the compressor ON
time, thereby displacing the cold air from the evapo-
rator coil and allowing the freezer compartment to
be chilled.
The function cannot be activated in the presence of
alarm signals. Activation of an alarm mode or switch-
ing off the appliance automatically causes this func-
tion to be deactivated.
This function is deactivated in the following cases:
pressing the relative button again; automatically,
when the maximum activation time (24 hours) is
reached; when the freezer air temperature sensor
detects a temperature below a value parameterised
in the EEPROM for a time parameterised in the
memory.
When the function is deactivated the appliance
resumes the operating mode defined previously by
the user. The ECO or HOL
I
DAY functions can be
selected, although they will only become operational
when the SUPER FREEZER procedure has termi-
nated.
I
n the case of a faulty freezer air sensor this func-
tion is timer controlled.
I
n case of electrical power failures the function will
be reactivated automatically when power is restored,
completing the remaining hours, unless a tempera-
ture alarm occurs in this interval.
SUP
E
R COOL FUNCTION:
When the SUPER COOL function is inhibited the
appliance returns to the setting that was active be-
fore the SUPER COOL function was selected.
The user can also activate the ECO or HOL
I
DAY
functions, which will become operational as soon as
the SUPER COOL function has been deactivated. The
SUPER COOL function cannot be activated if the HOL
I
-
DAY function is active.
I
n the case of a faulty refrigera-
tor air sensor, this function is timer controlled.
I
n case of electrical power failures the function is
resumed automatically when power is restored, com-
pleting the remaining cycles, except in the presence
of a temperature alarm.
This function allows optimal chilling of large quanti-
ties of food in the refrigerator compartment by alter-
ing the refrigerator On and Off set-points in accord-
ance with parameters stored in the EEPROM
memory and it is maintained for the number of cy-
cles stored in the memory. The cold air transferred
by the fan via the damper serves to chill the refrig-
erator compartment.
The SUPER COOL function cannot be activated if
either of the two alarm modes is active.
Activation of an alarm mode or switching off the ap-
pliance or only the refrigerator compartment auto-
matically causes this function to be deactivated.
Activation of the SUPER COOL function can be per-
formed by the user pressing button (1) in which case
LED (3) will illuminate to confirm the function is ac-
tive; the function is deactivated by the user pressing
the button again, or it will be deactivated automati-
cally at the end of the procedure (number of cycles)
as defined in the EEPROM memory.